Fogging is a non-invasive technique based on the use of positive spherical power lenses to relax accommodation during refraction that is commonly used as an alternative to cycloplegic drugs. Although the mechanism of the fogging technique has been described, some aspects of its methodology remain unclear. The main purpose of this work was to determine which lens power and time of application are more suitable for achieving a successful relaxation of accommodation by analyzing the changes in accommodation when fogging lenses of different powers were placed in front of the participants’ eye for a certain timespan. The results of this analysis showed, in general, that low-power lenses and timespans of less than half a minute provided the highest relaxation of accommodation. However, high inter-subject variability was found in the two variables (power and time).
机译:雾化是一种非侵入性技术,基于使用正球面屈光镜片来放松屈光过程中的调节,通常用作睫状肌麻痹药物的替代品。尽管已经描述了雾化技术的机制,但其方法的某些方面仍不清楚。这项工作的主要目的是通过分析将不同度数的雾化镜片放置在参与者眼前一定时间跨度时的调节变化,确定哪种镜片度数和使用时间更适合成功实现调节放松。该分析的结果表明,一般来说,低倍率镜头和不到半分钟的时间跨度提供了最高的调节放松效果。然而,在两个变量 (功效和时间) 中发现了较高的主体间变异性。