A Preliminary Attempt to Profile Tympanometric Measures in Infants Using High Frequency Probe Tones

机译:初步尝试使用高频探查音对婴儿进行鼓室测温

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

There is dearth of published data on high frequency tympanometric measures for infants in Indian context. Aim of present study was to profile Peak compensated static acoustic admittance (Ytm), Tympanometric peak pressure (TPP), Tympanometric width (TW) and Equivalent ear canal volume (Vea) in infants. Cross-sectional study on 50 infants with present TEOAEs and with risk indicators for hearing loss. Tympanometry was performed using GSI-Tympstar for 678 and 1000 Hz probe tones. Descriptive statistics were used to determine mean, SD and minimum and maximum for both genders. Using 678 Hz, Ytm ranged from 0.09 to 1. 48 mmho (males) and 0.11 to 1.14 mmho (females), while with 1000 Hz ranged from 0.15 to 1.49 (males) and 0.13–1.61 mmho (females). Using 678 Hz, TPP ranged from −95 to 70 daPa (males) and −155 to 80 daPa (females), while with 1000 Hz ranged from −75 to 95 daPa (males) and −145 to 50 daPa (females). Using 678 Hz, TW ranged from 30 to 190 daPa (males) and 40–23 daPa (females), while with 1000 Hz ranged from 60 to 210 daPa (males) and 40–183 daPa (females). Using 678 Hz, Vea ranged from 0.11 to 1.7 mmho (males) and 0.14–2.5 mmho (females), while with 1000 Hz ranged from 0.14 to 2.0 mmho (males) and 0.14–3.6 mmho (males). This study was a preliminary attempt to profile the tympanic measures. Ytm values were lesser or similar to other studies, TPP and Vea values had lower and narrow range, while TW were more than previous studies.
机译:在印度,缺乏针对婴儿的高频鼓室测量方法的公开数据。本研究的目的是剖析婴儿的峰值补偿静态声纳(Ytm),鼓室峰值压力(TPP),鼓室宽度(TW)和等效耳道体积(Vea)。对50名目前TEOAE并有听力损失风险指标的婴儿进行横断面研究。使用GSI-Tympstar对678和1000 Hz探针音进行鼓室测压。描述性统计数据用于确定均值,标准差以及最小和最大性别。使用678 Hz时,Ytm的范围为0.09至1.48 mmho(男性)和0.11至1.14 mmho(女性),而1000 Hz的范围为0.15至1.49(男性)以及0.13–1.61 mmho(女性)。使用678 Hz时,TPP的范围为−95至70daPa(男性),− 155至80daPa(女性),而1000 Hz的范围为−75至95daPa(男性)和−145至50daPa(女性)。使用678 Hz时,TW的范围为30至190 daPa(男性)和40-23 dada(女性),而1000 Hz时的范围为60至210 daPa(男性)和40–183 daPa(女性)。使用678 Hz时,Vea的范围为0.11至1.7毫米(男性)和0.14至2.5毫米(女性),而1000 Hz的范围为0.14至2.0毫米(男性)和0.14至3.6毫米(男性)。这项研究是剖析鼓膜措施的初步尝试。 Ytm值较小或与其他研究相似,TPP和Vea值的范围较小且较窄,而TW较以前的研究更大。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号