Vibration perception threshold was measured with a biothesiometer by a single observer at both medial malleoli and both big toes in 110 diabetic patients aged 15-65 selected at random and in 64 non-diabetic subjects aged 20-65. The vibration perception threshold showed appreciable individual variation both between contralateral sites and between ipsilateral sites, differing by at least 30% between the big toes in 26 (24%) of the diabetic patients and 16 (25%) of the non-diabetic group. Variability between sites was significantly greater in the diabetics than the normal subjects. The vibration perception threshold exceeded published normal values at one or more sites in 22 of the diabetic patients but at all four sites in only four.The wide variability in vibration perception threshold among sites may be due to the tissue characteristics locally and, in diabetic patients, possibly to asymmetric neuropathy. Biothesiometer readings at single or unilateral sites may be unrepresentative or misleading.
机译:振动观察阈值是由一名生物观察者通过随机选择的110名15-65岁糖尿病患者和64名20-65岁非糖​​尿病患者的内踝和两个大脚趾用生物体温计测量的。振动知觉阈值显示对侧部位之间和同侧部位之间存在明显的个体差异,在糖尿病患者的26名(24%)和非糖尿病组的16名(25%)中,大脚趾之间至少相差30%。糖尿病患者中位点之间的变异性显着大于正常受试者。在22位糖尿病患者中,一个或多个部位的振动知觉阈值超过了已公布的正常值,但在仅四个部位的所有四个部位中,振动知觉阈值的较大差异可能是由于局部以及糖尿病患者的组织特征引起的,可能是非对称性神经病。在单侧或单侧部位的生物体温计读数可能没有代表性或误导性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号