首页> 中文期刊> 《世界临床病例杂志》 >Dellen-like keratopathy associated with glaucoma drainage devices

Dellen-like keratopathy associated with glaucoma drainage devices

         

摘要

To report the first case of dellen-like keratopathy with superior corneal thinning associated with implantation of glaucoma drainage devices.A 70-year-old male with a history of primary open angle glaucoma and dry eye disease underwent placement of glaucoma drainage devices with antimetabolite application in both eyes.Prior to placement,minimal refractive error was noted on manifest refraction.Several years later,the patient was referred for decreased vision and corneal irregularity.Examination showed pathologic corneal curvature,superior corneal thinning,and epithelial demarcation lines immediately anterior to the glaucoma drainage devices in both eyes.The epithelium remained intact with no evidence of limbal stem cell deficiency.Manifest refraction revealed a large change in both eyes.Topography was used to confirm the presence of irregular corneal curvature anterior to the glaucoma drainage devices.Dellen-like keratopathy with superior thinning is a rare sequela after implantation of a glaucoma drainage device that must be considered in elderly patients who undergo glaucoma surgery.It is likely related to a combination of tear film alteration related to previously large anterior blebs,antimetabolite application,and aqueous humor flow patterns around the drainage devices.Treatment should focus on lubrication.

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信