首页> 中文期刊> 《放射学实践 》 >双源 CT 低管电压结合低浓度对比剂在肝脏增强扫描中的应用

双源 CT 低管电压结合低浓度对比剂在肝脏增强扫描中的应用

             

摘要

目的:探讨双源 CT 使用低管电压(100 kVp)和低浓度等渗对比剂(270 mg I/mL)进行肝脏增强扫描的可行性。方法:将我院108例行肝脏 CT 增强扫描的患者随机分成两组,每组54例。A 组:管电压100 kVp,对比剂为威视派克(270 mg I/mL)。B 组:管电压120 kVp,对比剂为碘克沙醇(320 mg I/mL)。测量、计算两组图像的对比噪声比(CNR)、信噪比(SNR)、肝实质 CT 值、肝动脉 CT 值、门静脉 CT 值及有效辐射剂量(ED),并对两组图像进行主观评分,对两组间上述指标进行统计学分析。结果:A 组的 CNR 高于 B 组,且差异具有统计学意义(t =2.88,P <0.05),SNR 高于 B 组(P <0.05),A 组能够提供清晰的诊断图像,提高病变的显示;A、B 组的图像质量评分差异无统计学意义(t =-0.58,P >0.05);A、B 组的肝实质 CT 值及肝动脉 CT 值均无统计学差异(t=-1.81,P >0.05;t=0.96,P >0.05),而 A 组的门静脉CT 值高于 B 组(t=7.55,P <0.05);A 组的三期总辐射剂量[(8.04±1.12)mSv]低于 B 组[(11.62±2.41)mSv](t =9.94,P <0.001)。结论:双源 CT 肝脏增强扫描采用管电压100 kVp 和低浓度等渗对比剂(270 mg I/mL)可以提供较好的图像 CNR,提高门静脉 CT 值,保证诊断图像质量的同时降低辐射剂量。%Objective:To explore the feasibility of dual-source CT using low tube voltage 100kVp and low concentra-tion 270mg I/mL isotonic contrast medium in enhanced imaging of the liver.Methods:108 patients having undergone CT en-hanced imaging were randomly divided into two groups:54 in each group.Group A:tube voltage was 100kVp,and contrast agent being visipaque (270mg I/mL).Group B:tube voltage was 120kVp,and contrast agent being iodixanol (320mg I/mL).Image contrast-to-noise ratio (CNR),image signal-to-noise ratio (SNR),hepatic parenchyma CT value,hepatic ar-tery CT value,and portal vein CT value were recorded and calculated.All the images of the two groups were given subjec-tive ratings and statistical analyses were made for all data of the groups.Results:The image contrast-to-noise ratio and sig-nal-to-noise ratio of group A were higher than that of group B,the difference was statistically significant (P <0.05),thus improving the display of the pathological changes.Scores for image noise and image quqlity were similar between the two groups,having no statistical significance (P >0.05).Liver parenchyma and hepatic artery CT values of the two groups had no statistical difference (P >0.05).Portal vein CT value of group A was higher than that of group B (P <0.05).The total radiation dose of three phases in groups A [(8.04±1.12)mSv]was lower than that in group B [(11.62±2.41)mSv,P <0.001],being reduced by about 30%.Conclusion:Dual-source CT enhancement imaging of the liver using tube voltage 100kVp and isotonic contrast medium in low concentration 270mg I/mL can provide better image contrast to noise ratio,in-crease the portal vein CT value,and reduce significantly the radiation dose on the basis of ensuring the quality of diagnostic images.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号