The efficiency of particle screening was studied over a range of vibrational parameters including amplitude, frequency and vibrational direction. The Discrete Element Method (DEM) was used to simulate the screening process. A functional relationship between efficiency and the parameters, both singly and combined, is established. The function is a complicated exponential. Optimal amplitude and frequency values are smaller for particles near the mesh and larger for other particles. The optimum vibration angle is 45° for nearly all kinds of particles. A transverse velocity, V⊥, was defined and V⊥=0.2 m/s was identified to be the most efficient operating point by both simulation and experimental observation. Comparison of these results with those reported by others is included.