首页> 外文期刊>海南医科大学学报(英文版) >The value of real-time three-dimensional echocardiography in evaluating left ventricular function for different degrees of heart failure
【24h】

The value of real-time three-dimensional echocardiography in evaluating left ventricular function for different degrees of heart failure

机译:实时三维超声心动图在评估左心室功能中的不同心力衰竭

获取原文
获取原文并翻译 | 示例
       

摘要

Objective:To explore the value and feasibility of real-time three-dimensional echocardiography(RT-3DE)in evaluating left ventricular function in patients with different degrees of heart failure.Methods:The 60 heart failure patients in the case group were divided into three subgroups according to the New York Heart Association(NYHA)classification:12 cases of cardiac function gradeⅡ,35 cases of cardiac function gradeⅢ,13 cases of cardiac function grade IV,and the other 30 cases of healthy subjects as control group.Compare the left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular ejection fraction(LVEF),and left ventricular 16,12,and 6 segments reaching the minimum systolic volume time standard deviation standardized value(Tmsv SD%),left ventricular 16,12 and 6 segments reaching the minimum systolic volume time standardized values of the maximum difference(Tmsv DIF%),analysis of the correlation between the above left ventricular function-related parameters and cardiac function grading.Results:(1)There were statistically significant differences in LVEDV and LVESV between each group(p<0.001).There was no statistically significant difference in LVEF between the cardiac function gradeⅡgroup and the control group,and between the grade IV group and the gradeⅢgroup(p=0.094 and 0.246).(2)compared with the control group,all parameters related to RT-3DE evaluation of left ventricular synchronization were prolonged in the case group,and the difference was statistically significant(p<0.001).The differences of Tmsv 16-SD%and Tmsv 16-DIF%in each subgroup of the case group were statistically significant(p<0.001).(3)LVEF was negatively correlated with NYHA classification of cardiac function(rs=-0.779,p<0.001),and LVEDV,LVESV,Tmsv 16-SD%,Tmsv 12-SD%,Tmsv 6-SD%,Tmsv 16-DIF%,Tmsv 12-DIF%,Tmsv 6-DIF%were positively correlated with NYHA function classification,showing strong correlation(rs=0.710,0.785,0.885,0.675,0.605,0.885,0.695,0.622,p<0.001),among them,Tmsv 16-SD%and Tmsv 16-Dif%have the highest correlation.Conclusion:RT-3DE can comprehensively evaluate the impairment of cardiac function.The measured parameters of left ventricular function are strongly correlated with cardiac function classification,which has impo-rtant application value for clinical judgment of the severity of heartfailure.
机译:目的:探讨实时三维超声心动图(RT-3DE)在不同心力衰竭患者评估左心室功能方面的价值和可行性。方法:案例组中的60例心力衰竭患者分为三个根据纽约心脏协会(NYHA)分类的亚组:12例心脏函数Ⅱ级,35例心脏函数Ⅲ,33例心脏函数等级,以及其他30例健康受试者为COPPLE GROUP.COMPARE左侧室内舒张性体积(LVEDV),左心室收缩量(LVERV),左心室喷射分数(LVEF)和左心室16,12,以及6个段达到最小收缩量时间标准偏差标准化值(TMSV SD %),左心室16,12和6个段达到最小收缩体积时间标准化值的最大差(TMSV差异),分析上述左心室功能之间的相关性 - 相关的参数和心功能分级。结果:(1)每组之间存在统计学上的LVEV和LVEVV(P <0.001)。心脏功能Ⅱ级群和对照组之间的LVEF没有统计学意义差异, IV级和Ⅲ级之间的Ⅲ级(P = 0.094和0.246)。(2)与对照组相比,在病例组中延长了与RT-3DE评估的所有参数,差异是统计学意义(P <0.001)。案例组的每种亚组中TMSV 16-SD%和TMSV 16-差异的差异有统计学意义(P <0.001)。(3)LVEF与心功能的NYHA分类负相关( Rs = -0.779,p <0.001)和Lvedv,LVEV,TMSV 16-SD%,TMSV 12-SD%,TMSV 6-SD%,TMSV 16-DIF%,TMSV 12-DIF%,TMSV 6-DIF%与Nyha功能分类呈正相关,表现出强烈的相关性(Rs = 0.710,0.785,0.885,0.675,0.605,0.885,0.695,0.622,p <0.001),其中,TMSV 16-SD%和TMSV 16-DIF%具有最高的相关性。结论:RT-3DE可以全面评估心功能的损伤。左心室功能的测量参数与心功能强烈相关分类,对心脏严重程度的临床判断具有常规应用价值。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号