首页> 中文期刊>振动与冲击 >B类风场与台风风场下输电塔的风振响应和风振系数

B类风场与台风风场下输电塔的风振响应和风振系数

     

摘要

为研究常规B类风场与台风风场下输电塔的风振响应差异,以沿海地区某四回路角钢输电塔为原型建立了有限元模型,采用谐波叠加法生成两类风场下的风速时程,并在时域内进行了输电塔风振响应和风振系数的数值分析.结果表明:台风风场的高湍流特性导致其作用时各测点的顺风向风振响应均大于B类风场下的对应值.两类风场下,输电塔的风振系数比值约为1.25.因此,台风多发地区的输电塔设计必须考虑台风高湍流引起的动力风荷载增大效应.此外还进行了气弹模型风洞试验,以研究不同风速下的气动响应和风振系数,并将试验结果与理论计算进行了分析比较,验证了数值分析的适用性.%A numerical analysis on the wind-induced response of a four-circuit angle-steel transmission tower under conventional terrain B wind field and typhoon wind field was performed. A FEM model was established, and the dynamic response was calculated under a fluctuating wind field simulated by using harmonic wave superimposing method. Based on data of numerical analysis, wind-induced responses under each wind field were discussed. Essential conclusions are as follows; high turbulence and strong variability of typhoon wind field have great influence on the response of transmission towers. The RMS of acceleration under typhoon wind field is larger than that under terrain B wind field. Under the two types of wind fields, the average ratio of wind load factor is about 1.25. Therefore, the design of transmission towers in typhoon-prone areas should take the fluctuating wind load magnification effect into consideration. Furthermore, the wind tunnel test on an aeroelastic model of the transmission tower was performed to study its wind-induced responses under different velocity. The test results were compared with theoretical values and the accuracy of the numerical analysis was verified.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信