首页> 中文期刊> 《福建分析测试》 >火焰原子吸收光谱法测定三硅酸镁中镁的含量

火焰原子吸收光谱法测定三硅酸镁中镁的含量

         

摘要

To establish a method to determine magnesium in magnesium trisilicate. Method: The sample was handled by Microwave Digestion System, the content of magnesium in the samples was determinated by FAAS. Result: The good linear relation was determined as 0.05-0.4 mg.L-1 in magnesium by FAAS with a regression coeffcient of 0.9995. The average recovery rate was 98.4%-102.9% ;The relative standard deviation was 1.5%. Conclusion:The method was simple, rapid and accurate, and can be used for quality control of magnesium in magnesium trisilicate.%目的:建立三硅酸镁中镁的含量测定方法。方法:样品微波消解处理后,火焰原子吸收光谱法测定样品中镁的含量。结果:镁在0.05-0.4mg/L范围内线性关系良好,相关系数为0.9995;回收率在98.4%-102.9%,RSD为1.5%。结论:该方法简单、快速、准确;能很好地用于三硅酸镁中镁的质量控制。

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号