首页> 中文期刊> 《防爆电机》 >高压水泵电机软启动分析

高压水泵电机软启动分析

         

摘要

This paper briefly introduces basic parameters of the high-voltage water pump motor, describes method and theory of soft start conducted by switch transformer. Starting fail-ure of the motor caused by mismatch of the relay when the network voltage is too low is emphati-cally analyzed. Starting voltage drop of the motor under different voltage is calculated in detail, and the reason why the motor cannot start normally is obtained. By voltage compensation, relay protection and other methods, the water pump motor can normally start.%简要介绍了高压水泵电机的基本参数,该电机采用开关变压器式进行软启动的方式和原理。着重对该电机在电网电压低的情况下因继电保护配合不当造成起动失败进行分析,并对其在不同电压下的起动压降进行详细计算,最终得出该电机不能正常起动的原因,通过电压补偿和继电保护等方式,使水泵电机能正常起动。

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号