首页> 外文期刊>中国化学工程学报:英文版 >Experimental Investigation of a Vertical Tubular Desalination Unit Using Humidification Dehumidification Process
【24h】

Experimental Investigation of a Vertical Tubular Desalination Unit Using Humidification Dehumidification Process

机译:立式管式除湿加湿除湿工艺的实验研究

获取原文
获取原文并翻译 | 示例
       

摘要

A vertical tubular desalination unit with shell and tube structure was built to perform humidification and dehumidification simultaneously on the tube and shell side of the column, respectively. The effects of several operating conditions on the productivity and thermal efficiency of the column were investigated. The results show that both the productivity and thermal efficiency of the column enhance with the elevation of the inlet water temperature. The flow rates of water and carrier gas both have optimal operating ranges, which are 10-30 kg·h-1 and 4-7kg·h-1 for the present column, respectively. Meanwhile, the increase of external steam flow rate will promote the productivity of the column but reduce its thermal efficiency.
机译:构建具有壳和管结构的垂直管状脱盐单元,以分别在塔的管和壳侧同时进行加湿和除湿。研究了几种操作条件对色谱柱生产率和热效率的影响。结果表明,随着进水温度的升高,色谱柱的生产率和热效率均得到提高。水和载气的流速均具有最佳操作范围,本色谱柱分别为10-30 kg·h-1和4-7kg·h-1。同时,外部蒸汽流量的增加将提高塔的生产率,但会降低其热效率。