Overall dispersed side volumetric mare transfer coeffcieats for protein and amino acids were measured in continuous countercurreat PEG4000/KHP aqueous two-phase systems in a 57 mm I.D. packed extraction column. A model for overall dispersed side volumetric mass transfer coefficients was derived by describing the motion of the drops based upon Navier-Stokes equation combined with the relationship between mass transfer coefficients and the drop velocity. The model provides good predictions and can be successfully used in aqueous two-phase extraction. The awrage relative deviation between calculated values and experimental date ranges from 8% to 14%.