首页> 中文期刊> 《中国癌症研究:英文版》 >ENZYME-LINKED IMMUNOSORBENT ASSAY OF HUMAN PLACENTA TYPE GLUTATHIONE S-TRANSFERASE AND ITS APPLICATION IN THE DIAGNOSIS OF HEPATOCARCINOMA

ENZYME-LINKED IMMUNOSORBENT ASSAY OF HUMAN PLACENTA TYPE GLUTATHIONE S-TRANSFERASE AND ITS APPLICATION IN THE DIAGNOSIS OF HEPATOCARCINOMA

         

摘要

GST-π was purified from human placenta and its antiserum was raised in rabbits. The antibody IgC was purified and degraded into Fab’ fragment which was conjugated with horseradish peroxidase (HRP) using N-succinimidyl-4-(N-maleimido-methyl) cyclo-hexane-1-carboxylate (SMCC) as crosslinking reagent to produce Fab’-HRP conjugate. A sandwich ELISA was established for the microquantitative determination of GST-π. The sensitivity was 11 pg/tube, which was far more sensitive than the radioimmunoassay so far reported. Using this method, the serum GST-π of 41 cases normal adult was found to be 1.06±0.94 ng/ml. The upper limit of the normal value was 2.6 ng/ml. In 30 cases of primary hepatocarcinoma, the level of serum GST-π was 24.4± 17.4 ng/ml, which was 23 times higher than the normal average value (P0.01). The positive rate was 90%. In contrast, serum GST-π in 25 cases of chronic hepatitis was determined to be 1.74±1.16 ng/ml, which was not significantly different from the normal value (P0.05).

著录项

  • 来源
    《中国癌症研究:英文版》 |1991年第2期|78-81|共4页
  • 作者

    林峰; 陈惠黎;

  • 作者单位

    Department of Biochemistry;

    Shanghai Medical University;

    Department of Biochemistry;

    Shanghai Medical UniversityST-π was purified from human placenta and its antiserum was raised in rabbits. The antibody IgC was purified and degraded into Fab' fragment which was conjugated with horseradish peroxidase (HRP) using N-succinimidyl-4-(N-maleimido-methyl) cyclo-hexane-1-carboxylate (SMCC) as crosslinking reagent to produce Fab'-HRP conjugate. A sandwich ELISA was established for the microquantitative determination of GST-π. The sensitivity was 11 pg/tube;

    which was far more sensitive than the radioimmunoassay so far reported. Using this method;

    the serum GST-π of 41 cases normal adult was found to be 1.06±0.94 ng/ml. The upper limit of the normal value was 2.6 ng/ml. In 30 cases of primary hepatocarcinoma;

    the level of serum GST-π was 24.4± 17.4 ng/ml;

    which was 23 times higher than the normal average value (P<0.01). The positive rate was 90%. In contrast;

    serum GST-π in 25 cases of chronic hepatitis was determined to be 1.74±1.16 ng/ml;

    which was not significantly different from the normal value (P>0.05). The pseudo-positive rate was 12.0%.;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 肿瘤学;
  • 关键词

    conjugated; hexane; carboxylate; reagent; degraded; purified; peroxidase; terminated; sandwich; raised;

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号