The use of electronic medical records in the operating room is becoming increasingly common. Anesthesia providers access electronic medical records on the anesthesia computer workstation, composed of a computer, keyboard, and mouse. Anesthesia providers engage in frequent patient contact, and hand hygiene among providers is variable (Jacobs and Xiong, 2012). This variability could lead to potential bacterial transmission from the patient onto surfaces that the provider touches. These surfaces have the potential to then serve as sources for patient contamination if they are not decontaminated.;Approximately one in 25 patients develop a healthcare-associated infection daily; these infections are extremely costly and contribute to prolonged length of stay in the hospital. These infections range from central line-associated infections, catheter-associated urinary tract infections, surgical site infections, and ventilator-associated pneumonia.;The preliminary study focused on swabbing the anesthesia computer workstation mouse the morning after general anesthesia cases were performed. The results of the preliminary study indicated that the anesthesia workstation computer mouse was contaminated with colony forming units (CFUs). The research study focused on swabbing the anesthesia workstation computer mouse the morning after general anesthesia cases were performed in that particular operating room suite, followed by the application of a germicidal wipe, and finally swabbing the computer mouse again. Application of a germicidal wipe to the computer mouse significantly decreased the presence of bacteria on the computer mouse. Combining the data from both studies, we concluded that the anesthesia workstation computer mouse was a potential source of CFU transmission. We also concluded that application of germicidal agents to the surface of the mouse decreases the presence of CFUs on the surface of the mouse.
机译:在手术室中使用电子病历变得越来越普遍。麻醉提供者可以在由计算机,键盘和鼠标组成的麻醉计算机工作站上访问电子病历。麻醉提供者经常与患者接触,提供者之间的手部卫生情况各异(Jacobs和Xiong,2012)。这种变化可能导致潜在的细菌从患者传播到提供者接触的表面。如果不进行净化,这些表面有可能成为患者污染的源头。每天约有25名患者中有1名患者出现与医疗相关的感染;这些感染的成本非常高,并且会导致住院时间延长。这些感染的范围包括中枢线相关感染,导管相关性尿路感染,手术部位感染和呼吸机相关性肺炎。初步研究的重点是在全身麻醉病例发生后第二天擦拭麻醉计算机工作站鼠标。初步研究结果表明,麻醉工作站计算机鼠标被集落形成单位(CFU)污染。该研究的重点是在特定的手术室套件中进行全身麻醉后,在第二天早上擦拭麻醉工作站计算机鼠标,然后使用杀菌擦拭布,最后再次擦拭计算机鼠标。将杀菌抹布应用于计算机鼠标可显着减少计算机鼠标上细菌的存在。结合两项研究的数据,我们得出结论,麻醉工作站计算机鼠标是CFU传播的潜在来源。我们还得出结论,将杀菌剂应用于小鼠表面可减少CFU在小鼠表面的存在。

著录项

  • 作者

    Beussink, Erika.;

  • 作者单位

    Webster University.;

  • 授予单位 Webster University.;
  • 学科 Microbiology.
  • 学位 M.S.
  • 年度 2018
  • 页码 41 p.
  • 总页数 41
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号