首页> 外文学位 >A comparative analysis of angular cephalometric values between CBCT generated lateral cephalographs versus digitized conventional lateral cephalographs.
【24h】

A comparative analysis of angular cephalometric values between CBCT generated lateral cephalographs versus digitized conventional lateral cephalographs.

机译:比较CBCT生成的侧向头颅造影剂和数字化常规侧向头颅造影剂之间的角度头颅测量值。

获取原文
获取原文并翻译 | 示例

摘要

Objectives. (1) To determine precision of angular measurements in both the 2D and 3D imaging systems, and to (2) to ascertain the difference in cephalometric values between traditional and CBCT generated cephalographs.;Results. High inter-rater reproducibility (ICC>0.8) with all angles was demonstrated in both imaging modalities. Only SN-FH (Conventional 95% CI: 0.584-0.965; CBCT 95% CI: 0.584-0.950) demonstrated significant difference between raters. No significant difference in the angular measurements was detected between the two image modalities (p>0.1 for all measurements, alpha=0.05).;Conclusions. A lateral, full thickness x-ray construction from CBCT imaging (NewTom 3G) can be used to perform traditional cephalometric analysis with comparable levels of precision and accuracy.;Methods. Traditional cephalograms (Orthoceph OC100) and volumetric CBCT imaging (Newtom 3G) were performed on 36 patients from the incoming pool of treatable cases at the University of Alberta Graduate Orthodontic Clinic, Edmonton. Lateral cephalometric analysis using Dolphin 3D was performed and ten angular measurements were evaluated. Inter-rater and Intra-rater reliability was assessed using inter-rater correlation coefficient (ICC). Paired MANOVA was used to compare differences in measurements between the two image modalities.
机译:目标。 (1)确定2D和3D成像系统中角度测量的精度,并(2)确定传统和CBCT生成的头颅造影仪之间的头颅测量值差异。在两种成像方式中,所有角度均具有较高的评分者间可重复性(ICC> 0.8)。只有SN-FH(常规95%CI:0.584-0.965; CBCT 95%CI:0.584-0.950)在评估者之间显示出显着差异。在两个图像模态之间未检测到角度测量值的显着差异(对于所有测量值,p> 0.1,α= 0.05)。来自CBCT成像(NewTom 3G)的横向,全厚度X射线构造可用于执行传统的头颅测量分析,其精确度和准确性相当。在阿尔伯塔大学埃德蒙顿分校正畸诊所接受治疗的病例中,对36例入院患者进行了传统的头颅造影(Orthocepheph OC100)和CBCT体积成像(Newtom 3G)。使用Dolphin 3D进行了侧向头影测量,并对十个角度测量进行了评估。使用评定者间相关系数(ICC)评估评定者间和评定者内的可靠性。配对的MANOVA用于比较两个图像模态之间的测量差异。

著录项

  • 作者

    Chung, Raymond Rhin.;

  • 作者单位

    University of Alberta (Canada).;

  • 授予单位 University of Alberta (Canada).;
  • 学科 Health Sciences Dentistry.
  • 学位 M.Sc.
  • 年度 2008
  • 页码 107 p.
  • 总页数 107