首页> 外文学位 >Long-term Effects of Cleaning Methods on Properties of Vivera and ACE Clear Retainer Materials.
【24h】

Long-term Effects of Cleaning Methods on Properties of Vivera and ACE Clear Retainer Materials.

机译:清洁方法对Vivera和ACE透明保持器材料性能的长期影响。

获取原文
获取原文并翻译 | 示例

摘要

Hypothesis: In the long term, ViveraRTM and EssixRTM ACE are not significantly different in transmittance, surface roughness, and flexural modulus among 7 cleaning methods.;Objective: Clear retainers have increased in popularity due to their esthetic nature. However, few studies have focused on long-term maintenance of these retainers. This study evaluated the long-term effects of 7 different cleaning methods on light transmittance, flexural modulus, and surface roughness of ViveraRTM material.;Methods: ViveraRTM retainer (Align RTM Technology) specimens (n=10,2x0.5x0.04in) were exposed to 7 different cleaning methods: InvisalignRTM cleaning crystals, PolidentRTM, ListerineRTM, 2.5% vinegar, 0.6% sodium hypochlorite, 3% hydrogen peroxide, and toothbrushing with distilled water twice a week for 6 months. Before treatment and after 6 months, light transmittance, flexural modulus, and surface roughness of specimens were quantified. Qualitative assessment of random specimens from each method was performed at 6 months using a scanning electron microscope. Mean difference comparisons were done using the independent student t-test and ANOVA (P<0.05). Results: A decrease in transmittance of specimens was found with all cleaning methods compared to baseline, with toothbrushing causing the greatest decrease for ViveraRTM and ListerineRTM causing the greatest decrease for ACE. Surface roughness was unaffected by the cleaning methods except NaOCl eliciting a difference in Vivera and Listerine with ACE. Quantitative analysis with SEM however showed negligible difference. Vinegar and toothbrushing showed an increase in flexural modulus in ViveraRTM, however when compared to each other, showed no difference. All methods increased modulus for ACE except for Invisalign Crystals. Hydrogen peroxide caused the greatest decrease in flexibility of ACE.;Conclusions: Over the long-term there is a gradual decrease in transmittance of clear retainers with certain solutions creating less translucency. Surface roughness and flexibility are generally unaffected in the long term but may be affected by oxiders.;Funding: AlignRTM Technology.
机译:假设:从长远来看,ViveraRTM和EssixRTM ACE在7种清洁方法中的透光率,表面粗糙度和挠曲模量方面无显着差异。;目的:透明的保持器由于其美学特性而越来越受欢迎。但是,很少有研究关注这些保持器的长期维护。这项研究评估了7种不同清洁方法对ViveraRTM材料的透光率,挠曲模量和表面粗糙度的长期影响。方法:采用ViveraRTM固位体(Align RTM Technology)标本(n = 10,2x0.5x0.04in)暴露于7种不同的清洁方法下:InvisalignRTM清洁晶体,PolidentRTM,ListerineRTM,2.5%的醋,0.6%的次氯酸钠,3%的过氧化氢,并每周两次用蒸馏水刷牙,持续6个月。在治疗前和6个月后,对样品的透光率,弯曲模量和表面粗糙度进行定量。使用扫描电子显微镜在6个月内对每种方法的随机样本进行定性评估。使用独立学生t检验和ANOVA进行均数差异比较(P <0.05)。结果:与基线相比,所有清洁方法的样本透射率均下降,其中牙刷导致ViveraRTM下降最大,而ListerineRTM引起ACE下降最大。表面粗糙度不受清洁方法的影响,但NaOCl会引起ACE的Vivera和Listerine产生差异。然而用SEM进行的定量分析显示差异可忽略不计。醋和牙刷在ViveraRTM中显示挠曲模量增加,但是当彼此比较时,显示无差异。除Invisalign晶体外,所有方法均会增加ACE的模量。过氧化氢导致ACE的柔韧性下降最大。结论:从长远来看,透明固位体的透射率逐渐降低,某些溶液产生的半透明性降低。表面粗糙度和柔韧性通常不会长期受到影响,但可能会受到氧化物的影响。;资金来源:AlignRTM技术。

著录项

  • 作者

    Agarwal, Manika.;

  • 作者单位

    University of Illinois at Chicago.;

  • 授予单位 University of Illinois at Chicago.;
  • 学科 Dentistry.
  • 学位 M.S.
  • 年度 2017
  • 页码 72 p.
  • 总页数 72
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 遥感技术;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号