Objective. To determine if the linear measurements made in Galileos CBCT in the presence of soft tissue using cadaver heads are accurate.;Materials and methods. CBCT images were obtained in Galileos CBCT device after placement of gutta percha markers, three to the facial and one to the lingual of the area of interest in the mandible. The CBCT orthoradial image showing perfect alignment of the lingual with a facial marker was selected as the plane of measurement. The distance between the most superior and most inferior point on the bone on the selected plane was measured electronically. The specimens were sectioned along this plane and physical measurements were obtained with digital calipers. Linear distance was measured between the most superior and most inferior point on the bone on the selected plane. This distance was measured in 6 specimens with calipers and compared to the distance measured on the corresponding CBCT images.;Results. A paired-sample t-test was used to determine whether the mean difference measurement value of two measurements at right side was significantly equal to zero. The data revealed that overall there was no statistically significant difference between CBCT and Physical measurement on right side (p=0.2298), left side (p=0.3554) and overall between CBCT and Physical measurements (p=0.2684).;Conclusions. Based on the statistical evaluation of the CBCT and Physical measurements it can be concluded that Galileos CBCT unit is reliable for evaluation of linear measurements between anatomic structures within the bone in the presence of soft tissues in the mandible specially for measuring height of available bone.
机译:目的。为了确定在伽利略CBCT中使用尸体头在软组织存在下进行的线性测量是否准确。;材料和方法。在放置牙胶标记后,在Galileos CBCT设备中获得CBCT图像,其中三个标记在下颌骨感兴趣区域的面部,三个标记在舌部。选择显示舌与面部标记完全对准的CBCT正射影像作为测量平面。以电子方式测量选定平面上骨骼上最上和最下点之间的距离。沿该平面切取样品,并使用数字卡尺进行物理测量。在选定平面上的骨骼的最高和最低点之间测量线性距离。用卡尺在6个样品中测量该距离,并将其与在相应的CBCT图像上测量的距离进行比较。使用配对样本t检验确定右侧两次测量的平均差测量值是否显着等于零。数据显示,总体而言,CBCT与右侧的物理测量值之间无统计学差异(p = 0.2298),左侧(p = 0.3554)以及CBCT与物理测量值之间的总体差异(p = 0.2684)。根据CBCT和物理测量的统计评估,可以得出结论,伽利略斯CBCT单元对于下颌骨中存在软组织的骨骼内部解剖结构之间的线性测量(特别是用于测量可用骨骼的高度)的评估是可靠的。

著录项

  • 作者

    Ganguly, Rumpa.;

  • 作者单位

    The University of Iowa.;

  • 授予单位 The University of Iowa.;
  • 学科 Health Sciences Radiology.
  • 学位 M.S.
  • 年度 2009
  • 页码 74 p.
  • 总页数 74
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 预防医学、卫生学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号