Despite the best of modern microsurgical skills, the functional result that is achieved following the repair of a severed peripheral motor nerve has usually been less than complete. In an attempt to reduce or prevent denervation atrophy we have devised a totally implantable system of electrical stimulation and have examined its effect on the target muscle of a repaired peripheral nerve. In this study, twenty New Zealand white rabbits were divided into two groups: in one group the rectus femoris muscle is electrically stimulated after microsurgical repair of the femoral nerve; whereas the control group undergoes microsurgical repair of the femoral nerve only. Comparing the muscles to their contralateral counterparts at eight weeks post-op we found that electrical stimulation resulted in (a) the retention of 79+/
机译:尽管拥有最好的现代显微外科技术,但是修复受损的周围运动神经后所获得的功能结果通常还不完整。为了减少或预防失神经萎缩,我们设计了一种完全可植入的电刺激系统,并研究了其对修复后的周围神经的目标肌肉的影响。在这项研究中,将二十只新西兰白兔分为两组:一组在股神经的显微外科手术修复后,对股直肌进行电刺激;另一组将股直肌进行电刺激。对照组仅对股神经进行显微外科修复。比较术后八周的肌肉与对侧肌肉,我们发现电刺激导致(a)保留79 + /