首页> 外文学位 >A new engineering approach for indoor air quality manangement in building.
【24h】

A new engineering approach for indoor air quality manangement in building.

机译:建筑中室内空气质量管理的新工程方法。

获取原文
获取原文并翻译 | 示例

摘要

In November 1993, the Government of HKSAR issued ' A Green Challenge for the Community', which was its second review of the 1989 White Paper. An IAQ Management Group launched the 'Guidance Notes for the Management of Indoor Air Quality in Offices and Public Places' (GN) together with 'A Guide on Indoor Air Quality Certification Scheme for Offices and Public Places' in September 2003. Nevertheless, the specification of 'good' and 'excellent' IAQ criteria have been taken up as acceptable IAQ design and management criteria by building consultants and managers. Unfortunately, it confuses more the IAQ objectives rather than improving or enhancing it. Hence, much of the resources have been wrongly designated.;In this study, a modified sampling protocol for IAQ has been developed, which can be shown to reduce resources requirements that is therefore particularly suitable for periodically monitoring of IAQ rendering a true protection of health and sustaining comfort. The philosophy in this study is to formulate the deficiency in order to render the accomplishment of intended objectives of the GN. Three main problem areas are identified: the lack of typical annual outdoor air quality profile, the difficulty in measuring pollutant emission rates and the undefined ventilation quality degradation.;Outdoor air quality is monitored at 14 locations in Hong Kong. This project takes tremendous effort in compiling over 8.9 millions data into an analyzable format. Not only the outdoor air quality in Hong Kong at these districts can be analyzed, but also an annual typical profile for each pollutant in each monitoring station is derived. To facilitate the ventilation calculation, a term 'pollutant inventory' in defined with a model on evaluation of emission rates of pollutants with high precision. Finally, a four-tier scheme is further elaborated into a pragmatic protocol for evaluation of ventilation quality degradation. This completes a protocol for ventilation management to determine optimum ventilation.;Managing acceptable IAQ is even more demanding as management cannot be totally relied on computation nor design. Therefore, an electronic IAQ manager is established as a novel development. It is welcome by the industry and is expected to innovate the IAQ management protocol.
机译:1993年11月,香港特别行政区政府发布了“社区绿色挑战”,这是对1989年白皮书的第二次审查。 IAQ管理小组于2003年9月发布了“办公室和公共场所室内空气质量管理指南”(GN)以及“办公室和公共场所室内空气质量认证计划指南”。建筑顾问和管理人员已将“良好”和“优秀”的室内空气质量标准视为可接受的室内空气质量设计和管理标准。不幸的是,它使IAQ的目标更加混乱,而不是改善或增强它。因此,许多资源被错误地指定。;在本研究中,已经开发了一种针对IAQ的修改后的采样协议,可以证明它减少了资源需求,因此特别适合于定期监视IAQ从而真正保护健康并保持舒适感。本研究的理念是解决缺陷,以实现GN预期目标的实现。确定了三个主要问题区域:缺乏典型的年度室外空气质量概况,难以测量污染物排放率以及不确定的通风质量下降。;对香港的14个地点的室外空气质量进行了监测。该项目花费大量精力将890万个数据编译成可分析的格式。不仅可以分析这些地区香港的室外空气质量,还可以得出每个监测站中每种污染物的年度典型概况。为了便于通风计算,定义了一个“污染物清单”一词,该模型具有用于高精度评估污染物排放率的模型。最后,将四层方案进一步细化为评估通风质量下降的实用协议。这样就完成了确定最佳通风的通风管理协议。由于无法完全依靠计算或设计来管理,因此管理可接受的IAQ的要求甚至更高。因此,电子IAQ管理器被确立为一项新颖的发展。它受到业界的欢迎,并有望创新IAQ管理协议。

著录项

  • 作者

    Wong, Chun Sing.;

  • 作者单位

    Hong Kong Polytechnic University (Hong Kong).;

  • 授予单位 Hong Kong Polytechnic University (Hong Kong).;
  • 学科 Engineering Architectural.;Environmental Health.
  • 学位 Ph.D.
  • 年度 2009
  • 页码 371 p.
  • 总页数 371
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:37:47

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号