首页> 外文学位 >The effects of disc wear and surface polishing on the flexure strength of Vita Mark II dental porcelain used with the Cerec CAD/CAM system.
【24h】

The effects of disc wear and surface polishing on the flexure strength of Vita Mark II dental porcelain used with the Cerec CAD/CAM system.

机译:圆盘磨损和表面抛光对与Cerec CAD / CAM系统一起使用的Vita Mark II牙科瓷器抗弯强度的影响。

获取原文
获取原文并翻译 | 示例

摘要

Part 1 of this study characterized the deterioration of Cerec diamond discs and the subsequent effect on the surface texture and strength of milled Vita Mark II porcelain.; Modulus of rupture for each group was 6.94 (SD = 0.69), 6.59 (SD = 0.59) and 8.18 (SD = 0.59) MPa. No significant differences were found over time between specimens cut with new or used discs. The effect of deep cuts by diamond particles in a fresh disc may off set latent stresses by a dull disc. Exceeding the estimated milling time up to 10% had no effect on Vita Mark II porcelain strength.; Part 2 of this study measured the effect of metallurgical polishing (graded SiC papers plus 0.05 {dollar}mu{dollar}m {dollar}rm Alsb2Osb3){dollar} of the pulpal, cavo- and occlusal surfaces of Vita Mark II porcelain restorations, measured in 3-point fracture.; Modulus of rupture was calculated and tested by ANOVA and Tukey's HSD test: Groups 0-IV broke at 8.0, 9.5, 9.9, 11.2 and 11.0 MPa, respectively. Significant differences (p {dollar}<{dollar} 0.05) existed between groups 0 & 2, 0 & 3, 0 & 4, 1 & 3, and 1 & 4.; Polishing the occlusal surface of Vita II ceramic improves the modulus of rupture 16%. Polishing three to four sides improves strength even more (29 or 27%) over unpolished bars.
机译:这项研究的第1部分描述了Cerec金刚石圆片的变质以及随后对研磨Vita Mark II瓷器的表面纹理和强度的影响。每组的断裂模量分别为6.94(SD = 0.69),6.59(SD = 0.59)和8.18(SD = 0.59)MPa。用新的或用过的圆盘切割的样品之间随时间的变化没有发现显着差异。新鲜圆盘中金刚石颗粒的深切效果可能会抵消钝盘造成的潜在应力。超过估计的研磨时间达10%对Vita Mark II瓷器强度没有影响。这项研究的第2部分测量了冶金抛光(渐变SiC纸加上0.05 {μm} m {dolal} rm Alsb2Osb3} {dolal}对Vita Mark II瓷修复体的牙髓,牙槽和咬合面的影响,在三点断裂中测量。通过ANOVA和Tukey的HSD测试来计算和测试破裂模量:0-IV组分别在8.0、9.5、9.9、11.2和11.0MPa下破裂。组0和2、0和3、0和4、1和3和1和4之间存在显着差异(p {美元} <{美元} 0.05)。抛光Vita II陶瓷的咬合面可使断裂模量提高16%。抛光三到四个侧面,与未抛光的钢筋相比,可进一步提高强度(29或27%)。

著录项

  • 作者

    David, Amy L.;

  • 作者单位

    University of Louisville.;

  • 授予单位 University of Louisville.;
  • 学科 Health Sciences Dentistry.; Engineering Biomedical.
  • 学位 M.S.
  • 年度 1998
  • 页码 60 p.
  • 总页数 60
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 口腔科学;生物医学工程;
  • 关键词

  • 入库时间 2022-08-17 11:48:31

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号