The goal of this doctoral project was the development, laboratory validation and field implementation of an indirect microenvironmental press sampler for dermal exposure estimation as a result of hand contact on a dust laden surface.;Characterization of seasonal variation in particle size fractions of household dusts deposited onto indoor surfaces in the home indicated that dust mass was greater during the summer than during the winter. The total number of particles deposited, however, was greater during the winter than during the summer. The increase in winter time particle number was caused by greater numbers of particles with an equivalent spherical diameter <2.5 mum. Since over 99% of the particles on indoor surfaces were smaller than 50 mum any indirect sampling technique for dermal exposure estimation should have collection efficiencies similar to the hand for particles smaller than 50 mum.;In controlled laboratory collection efficiency tests the Edwards-Lioy (EL) sampler collected 35 +/- 5% atrazine, 31 +/- 3% diazinon, 32 +/- 5% malathion and 18 +/- 3% chlorpyrifos from housedust laden surfaces. Pesticide collection efficiencies measured on the investigator's hand were 42 +/- 7%, 29 +/- 8%, 43 +/- 8% and 21 +/- 5%, respectively. The collection efficiencies of the two sampling techniques were highly correlated for atrazine, diazinon, and chlorpyrifos (correlation coefficient = 0.840, 0.815 and 0.706), but not for malathion (correlation coefficient = 0.086). Octanol/water partitioning coefficients for each pesticide indicated that the polarity of the compound was indicative of which variable (skin hydration or sebum) influenced collection efficiency of the skin.;Field validation of the EL sampler was performed as part of both the National Human Exposure Assessment Survey (NHEXAS)-Pesticide Module and the Minnesota Children's Pesticide Study. Median chlorpyrifos levels collected by the EL sampler were 20% of the average Values collected by the modified Lioy-Weisel-Wainman (LWW) wipe sampler. This was in close agreement with laboratory collection tests. The EL sampler collected similar atrazine and chlorpyrifos concentrations on both carpets and smooth surfaces (r2 = 0.81; p = 0.00001). Chlorpyrifos concentrations measured by the EL sampler showed no correlation with handrinse levels. Dust sampling methods were not good indicators of internal chlorpyrifos levels.
机译:该博士项目的目标是开发,实验室验证和现场实施间接微环境压力取样器,用于通过尘土表面上手接触而进行的皮肤暴露评估。;表征沉积的家用粉尘颗粒分数的季节性变化在家里的室内表面上发现,夏季的尘埃量大于冬季的尘埃量。但是,冬季沉积的颗粒总数要多于夏季。冬季颗粒数量的增加是由于当量球形直径小于2.5微米的颗粒数量增加所致。由于室内表面超过99%的颗粒小于50微米,因此任何用于皮肤接触评估的间接采样技术应具有与小于50微米的颗粒手相似的收集效率。;在受控实验室的收集效率测试中,Edwards-Lioy( EL)采样器从充满尘土的表面收集了35 +/- 5%的r去津,31 +/- 3%的二嗪农,32 +/- 5%的马拉硫磷和18 +/- 3%的毒死rif。在研究人员的手上测得的农药收集效率分别为42 +/- 7%,29 +/- 8%,43 +/- 8%和21 +/- 5%。两种采样技术的收集效率与阿特拉津,二嗪农和毒死rif具有高度相关性(相关系数= 0.840、0.815和0.706),而与马拉硫磷没有相关性(相关系数= 0.086)。每种农药的辛醇/水分配系数表明,该化合物的极性指示着哪个变量(皮肤水合作用或皮脂)影响皮肤的采集效率。评估调查(NHEXAS)-农药模块和明尼苏达州儿童农药研究。 EL采样器收集的毒死rif中位数为改良的Lioy-Weisel-Wainman(LWW)擦拭采样器收集的平均值的20%。这与实验室收集测试非常吻合。 EL采样器在地毯和光滑表面上均收集到了相似的阿特拉津和毒死rif浓度(r2 = 0.81; p = 0.00001)。 EL采样器测量的毒死rif浓度与手洗液水平无相关性。灰尘采样方法不是内部毒死levels含量的良好指标。

著录项

  • 作者

    Edwards, Rufus David.;

  • 作者单位

    Rutgers The State University of New Jersey, School of Graduate Studies.;

  • 授予单位 Rutgers The State University of New Jersey, School of Graduate Studies.;
  • 学科 Environmental science.;Public health.;Toxicology.
  • 学位 Ph.D.
  • 年度 1999
  • 页码 185 p.
  • 总页数 185
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号