首页> 外文学位 >Design and mechanical behavior of the MD series of bone dowels.
【24h】

Design and mechanical behavior of the MD series of bone dowels.

机译:MD系列接骨钉的设计和力学性能。

获取原文
获取原文并翻译 | 示例

摘要

Allograft bone dowels, developed at the University of Florida Tissue Bank, Inc (UFTB) and Regeneration Technologies, Inc (RTI), offer an alternative to the more conventional metallic and other synthetic dowels for spinal fusions. These dowels are machined from the long bone of human donor tissue. They are an advance over current implants because they possess the precise dimensional characteristics that are typical of metallic or other synthetic implants, are composed of mostly cortical bone, do not cause additional donor site morbidity associated with autografts, yet they retain the advantageous osteogenic characteristics of allografts and autografts.; Allograft and autograft tissues have a well-established history in spinal fusions. However, postoperative failures are commonly reported. These failures are due to the variations in geometric, material, and mechanical properties of the implants. In addition, little research effort has been placed on insuring that these types of implants have at least a minimum level of load bearing capacity.; The results of this research developed a novel method, based on statistical procedures and fracture mechanisms, that defines the strength of the MD-series of bone dowels and uses this technique to establish a nondestructive mechanical quality control procedure. In addition, the influence of donor characteristics such as age, and sex on the strength of the dowels was established. The role of different tissue banking processing steps on the strength of machined tissue was identified, as well as differences in strength among different dowel designs determined.
机译:由佛罗里达大学组织银行(UFTB)和再生技术有限公司(RTI)开发的同种异体骨钉为脊柱融合提供了更常规的金属钉和其他合成钉的替代品。这些销钉是从人类供体组织的长骨加工而成的。它们比目前的植入物具有优势,因为它们具有金属或其他合成植入物所特有的精确尺寸特征,主要由皮质骨组成,不会引起与自体移植相关的其他供体部位发病,但是它们保留了有利的成骨特性。同种异体移植和自体移植。同种异体移植和自体移植组织在脊柱融合术中已有悠久的历史。但是,术后失败通常被报道。这些失败是由于植入物的几何形状,材料和机械性能的变化。另外,很少有研究工作用于确保这些类型的植入物具有至少最小水平的承载能力。这项研究的结果开发了一种基于统计程序和断裂机制的新方法,该方法定义了MD系列骨销的强度,并使用此技术建立了无损机械质量控制程序。另外,建立了诸如年龄和性别之类的供体特性对销钉强度的影响。确定了不同的组织库加工步骤对加工的组织强度的作用,以及确定的不同销钉设计之间的强度差异。

著录项

  • 作者

    Bianchi, John R.;

  • 作者单位

    University of Florida.;

  • 授予单位 University of Florida.;
  • 学科 Engineering Materials Science.; Applied Mechanics.; Engineering Biomedical.
  • 学位 Ph.D.
  • 年度 1999
  • 页码 141 p.
  • 总页数 141
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工程材料学;应用力学;生物医学工程;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号