Debris is present in all pipelines and has the potential to cause debris-induced lift-off in magnetic flux leakage inspection tools. A test apparatus was developed to qualitatively examine the effect of debris-induced lift-off.; The results of this research indicate that debris-induced lift-off has a detrimental effect on magnetic flux leakage data. This increases the potential of pipeline defects being either undersized or missed.; To reduce or eliminate the effects of debris-induced lift-off, the pipeline should be regularly cleaned. This minimizes the occurrence of large accumulations of debris. If it is determined that debris is present in a pipeline, even in small quantities, the pipeline should be cleaned using the appropriate pipeline cleaning method. This improves the quality of the magnetic flux leakage inspection data and resulting integrity assessment.
机译:所有管道中都存在碎屑,并有可能在漏磁检测工具中引起碎屑引起的剥离。开发了一种测试设备,以定性地检查碎屑引起的剥离的影响。这项研究的结果表明,碎屑引起的剥离对磁通量泄漏数据有不利影响。这增加了管道缺陷过小或遗漏的可能性。为了减少或消除由碎屑引起的剥离的影响,应定期清洁管道。这样可以最大程度地减少碎片堆积的发生。如果确定管道中存在碎屑(即使是少量),则应使用适当的管道清洗方法清洗管道。这提高了磁通量泄漏检查数据和结果完整性评估的质量。

著录项

  • 作者

    Valentine, Francisco Louis.;

  • 作者单位

    West Virginia University.;

  • 授予单位 West Virginia University.;
  • 学科 Engineering Mechanical.
  • 学位 M.S.
  • 年度 2000
  • 页码 107 p.
  • 总页数 107
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 机械、仪表工业;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号