Synthetic winery wastewater was used to conduct efficacy studies of winery wastewater treatment using anaerobic digestion. Biological methane potential (BMP) and anaerobic toxicity assays (ATA) indicated that winery wastewater is a good candidate for anaerobic digestion. Both tannic acid and sulfite, common winery wastewater constituents, were shown to inhibit methane production.;A continuously stirred tank reactor (CSTR) system was applied to investigate the removal rate of chemical oxygen demand (COD) and phenolics, as well as methane generation. Hydraulic retention time (HRT) values of 2, 4, and 8 days were evaluated. While the 2- and 4-day systems failed, the 8-day HRT (0.675 g/L/d OLR) CSTR system was successful at removing COD (>80% removal), some phenolics, and produced biogas (avg. methane production 0.071 L/L/d).;Actual winery wastewater successfully validated the synthetic results, indicating agreement (R2 = 0.9758).
机译:合成酒厂废水用于进行厌氧消化处理酒厂废水的功效研究。甲烷生物潜力(BMP)和厌氧毒性测定(ATA)表明,酿酒厂废水是厌氧消化的良好候选者。单宁酸和亚硫酸盐,这是酿酒厂废水中的常见成分,均显示出抑制甲烷产生的作用。连续搅拌釜反应器(CSTR)系统用于研究化学需氧量(COD)和酚类的去除率以及甲烷的产生。评估了2、4和8天的水力停留时间(HRT)值。当2天和4天系统发生故障时,为期8天的HRT(0.675 g / L / d OLR)CSTR系统成功去除了COD(去除率> 80%),一些酚类化合物,并产生了沼气(平均产生甲烷) 0.071 L / L / d).;实际酿酒厂废水成功验证了合成结果,表明吻合(R2 = 0.9758)。

著录项

  • 作者

    Henrie, Michael E.;

  • 作者单位

    Utah State University.;

  • 授予单位 Utah State University.;
  • 学科 Engineering Agricultural.;Engineering Environmental.
  • 学位 M.S.
  • 年度 2005
  • 页码 116 p.
  • 总页数 116
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号