Stress corrosion cracking (SCC) susceptibility of the phosphorus de-oxidized copper has been evaluated in synthetic seawater polluted by sulfides using slow strain rate test (SSRT). The effect of concentration of sulfide, temperature, and applied cathodic and anodic potentials on the final strain values and maximum stress were also studied. No cracks were found under the tested conditions. The final strain and maximum stress values decreased but not significantly, with increase in the temperature, applied anodic potential and sulfide concentration. The observed effect is due to the section reduction by uniform corrosion. Lateral cross section and microscopic examination of the fractured specimen ruled out the existence of the localized corrosion. Electrochemical measurements showed that the Cu2S film is not a protective film and also exhibits a mass transfer limitation to the inward diffusion of the sulfides. Based on these results the reasons for the absence of cracking are also discussed.
机译:已使用慢应变速率测试(SSRT)在被硫化物污染的合成海水中评估了磷脱氧铜的应力腐蚀开裂(SCC)敏感性。还研究了硫化物浓度,温度以及施加的阴极和阳极电势对最终应变值和最大应力的影响。在测试条件下未发现裂纹。随着温度,施加的阳极电势和硫化物浓度的增加,最终应变和最大应力值下降但不明显。观察到的效果是由于均匀腐蚀导致的截面减小。侧向横截面和显微镜检查断裂的试样排除了局部腐蚀的存在。电化学测量表明,Cu2S膜不是保护膜,并且还表现出对硫化物向内扩散的传质限制。基于这些结果,还讨论了不产生裂纹的原因。

著录项

  • 作者

    Bhaskaran, Ganesh.;

  • 作者单位

    University of Toronto (Canada).;

  • 授予单位 University of Toronto (Canada).;
  • 学科 Engineering Chemical.
  • 学位 M.Sc.
  • 年度 2010
  • 页码 85 p.
  • 总页数 85
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号