Effect of contrast agents used in computed tomography simulation on inhomogeneity dose calculations for a three dimensional treatment planning system.

机译:在计算机断层扫描模拟中使用的造影剂对三维治疗计划系统的不均匀剂量计算的影响。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this study is to investigate the relationship between heterogeneity corrected dose calculations in the presence of iodine based contrast agents or with heterogeneity corrections and density assignment to a contrast containing organ. In addition, the study was used to assess a density assignment method to minimize any effects on dose calculations attributed to these contrast agents and assess how dose calculations using CT scans with contrast agents relates to the CT scanning kilo voltage technique. A two part study was conducted. Part one utilized a phantom constructed with a 236 ml container filled with varied concentrations of 60% Hypaque contrast agent (Diatrizoate Meglumine Injection, USP). The contrast filled container was mounted in an 8 cup bowl filled with saline solution. The phantom containing contrast was scanned while varying the independent variables of contrast concentration and scanning kilo voltage settings. Dose calculations were performed for computing monitor units necessary to deliver the prescribed dose. Second portion of the study utilized more lifelike conditions using contrast by selection of actual clinical cases. Data were derived from 30 case studies determined to have met the following characteristics: prostate cancer patients administered 4 cc of contrast mixed with 40 cc of saline administered using a retrograde technique to delineate the bladder on CT images. Cases were scanned using the standard 120 kVp technique and 3 mm slice thickness. This study utilizes a three dimensional treatment planning system employing an Anisotropic Analytical Algorithm (AAA) for the calculations. Dose Volume Histogram data, dose differences and Distance to Agreement (DTA) were evaluated in comparing the heterogeneity corrected and density overridden contrast containing organ calculations. This study concluded an increased density due to iodinated contrast agents is associated with an increased dose per monitor unit calculation for minimum dose to the Clinical Tumor Volume (CTV). A decreased scanning kilo voltage is associated with an increased dose per monitor unit calculation as well.Normal tissue density assignment to contrast containing organs is associated with an increase in calculated CTV dose. Though the findings were statistically significant the largest effects were observed in the phantom tests, clinical significance is small when utilizing low levels of contrast concentration. Any dose effects become clinically insignificant as the number of treatment fields is increased and the contrast concentration is decreased. Density assignment to the bladder for prostate treatment plans is a valuable option for increasing accuracy of the calculation when contrast HU's are high however, contrast concentrations normally used in the clinic will not significantly change the treatment plan, CTV dose or bladder dose by more than 1% if not employed.
机译:这项研究的目的是研究在存在基于碘的造影剂或异质性校正和密度分配给包含造影剂的器官时,异质性校正剂量计算之间的关系。此外,该研究还用于评估密度分配方法,以最大程度地减少归因于这些造影剂的剂量计算的任何影响,并评估使用CT扫描和造影剂进行剂量计算如何与CT扫描千伏电压技术相关。进行了两部分的研究。第一部分使用了一个幻影,该幻影是由一个236 ml的容器构成的,容器中装有不同浓度的60%Hypaque造影剂(Diatrizoate Meglumine Injection,USP)。将装满造影剂的容器安装在装有盐溶液的8杯碗中。扫描包含幻像的对比度,同时改变对比度浓度和扫描千伏电压设置的独立变量。进行剂量计算以计算输送规定剂量所必需的监控器单元。研究的第二部分通过选择实际的临床病例,通过对比利用了更多逼真的条件。数据来自30个确定满足以下特征的案例研究:前列腺癌患者使用4 cc造影剂与40 cc盐水混合,使用逆行技术在CT图像上描绘膀胱。使用标准的120 kVp技术和3 mm的切片厚度扫描病例。本研究利用采用各向异性分析算法(AAA)进行计算的三维治疗计划系统。通过比较校正的异质性和包含器官计算的密度覆盖对比度,评估了剂量体积直方图数据,剂量差异和一致距离(DTA)。这项研究得出的结论是,由于碘化造影剂导致的密度增加,与每个监护仪单位计算的剂量(针对临床肿瘤体积(CTV)的最小剂量)相关。降低的扫描千伏电压还与每个监控器单位计算的剂量增加有关。正常组织密度分配给包含造影剂的器官与计算的CTV剂量增加有关。尽管这些发现具有统计学意义,但在幻影测试中观察到的影响最大,但是当使用低浓度的对比剂时,临床意义很小。随着治疗范围的增加和造影剂浓度的降低,任何剂量效应在临床上都变得微不足道。当对比剂HU较高时,将前列腺密度分配给前列腺治疗计划是提高计算准确性的宝贵选择,但是,临床上通常使用的对比剂浓度不会显着改变治疗计划,CTV剂量或膀胱剂量超过1 %,如果不雇用。

著录项

  • 作者

    Veldkamp, Linda.;

  • 作者单位

    TUI University.;

  • 授予单位 TUI University.;
  • 学科 Health Sciences Radiology.Biophysics Medical.
  • 学位 Ph.D.
  • 年度 2010
  • 页码 125 p.
  • 总页数 125
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 医学心理学、病理心理学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号