Control of powder flow is very important in many industrial processes. Segregation is a problem that arises during powder flows. In the pharmaceutical industry, the variation of drug content in tablets may increase as a consequence of segregation. Intermolecular forces, particle size and different constituents in powdered mixtures may influence segregation, therefore, particle size and chemical constituent analysis are important in segregation studies. Near-Infrared Reflectance Spectroscopy (NIRS) has been applied as a potential online system for the detection of particle size changes and segregation during powder flow. Near-Infrared Reflectance Spectra are characterized by offsets and slopes of baselines. Both offsets and slopes are highly related to the particle size although offsets depend on the number of particles that reflect. The offset and slopes of the spectra provides information on the variation of the particle size and number of particles. In this work, three samples of lactose characterized by particle size by sieving were analyzed by NIRS. Two modes of sampling were utilized: static lactose and dynamic lactose falling through a vertical pipe. Spectra taken by dynamic mode showed a large distribution of offsets, explained by the variation in particle concentration during free fall. NIR spectra after eliminating offsets show two flow regimes during free fall. The first regime shows low apparent absorbance and the second regime shows constant apparent absorbance. Also, the samples with a larger particle size show less variation in variation in particle size. Spectra of mixtures falling freely also show that when lactose has a greater particle size, the segregation in chemical constituents is minimized. The results obtained indicate that after further development, the method developed could be used to monitor powder flows in industrial processes.
机译:在许多工业过程中,粉末流量的控制非常重要。分离是在粉末流动期间出现的问题。在制药工业中,由于分离,片剂中药物含量的变化可能会增加。分子间力,粒度和粉末混合物中的不同成分可能会影响偏析,因此,粒度和化学成分分析在偏析研究中很重要。近红外反射光谱(NIRS)已被用作潜在的在线系统,用于检测粉末流动过程中的粒度变化和偏析。近红外反射光谱的特征是基线的偏移和斜率。尽管偏移量和斜率都与粒子大小高度相关,但是偏移量取决于反射的粒子数。光谱的偏移和斜率提供了有关粒径和颗粒数量变化的信息。在这项工作中,通过NIRS分析了三个以筛分为特征的乳糖样品。利用了两种采样方式:通过垂直管落下的静态乳糖和动态乳糖。动态模式获得的光谱显示出较大的偏移量分布,这可以通过自由下落期间颗粒浓度的变化来解释。消除偏移后的NIR光谱显示自由落体期间的两种流动状态。第一种方案显示低的表观吸光度,第二种方案显示恒定的表观吸光度。同样,具有较大粒径的样品在粒径变化中显示出较小的变化。自由下落的混合物的光谱还表明,当乳糖具有较大的粒径时,化学成分中的偏析最小。获得的结果表明,经过进一步开发,所开发的方法可用于监测工业过程中的粉末流量。

著录项

  • 作者单位

    University of Puerto Rico, Mayaguez (Puerto Rico).;

  • 授予单位 University of Puerto Rico, Mayaguez (Puerto Rico).;
  • 学科 Chemistry Analytical.; Chemistry Pharmaceutical.
  • 学位 M.S.
  • 年度 2006
  • 页码 58 p.
  • 总页数 58
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 化学;药物化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号