Freeze-thaw durability of concrete with natural and recycled concrete aggregates using air entraining admixture.

机译:使用引气剂对天然和再生混凝土骨料的混凝土的冻融耐久性。

获取原文
获取原文并翻译 | 示例

摘要

Freezing and thawing cycles is one of the most damaging factors that affect the durability of concrete. The damages caused by the cyclic freeze-thaw action can be divided into two factors. The first factor is an increase in internal crack, which causes the loss in relative dynamic modulus (RDM) of the concrete and the second factor is surface scaling, which leads to weight loss of the concrete. In this study, the durability of concrete made by replacing natural coarse aggregates (NCA) with various percentages of recycled concrete aggregates (RCA). Also some tests have been conducted with the addition of air entraining admixture (AEA). Prior to mixing the concrete, both NCA and RCA were characterized to determine their suitability as a construction material. Concrete mixes consisting of 0, 20, 40, 60, 80, and 100% replacement (by weight) of NCA with RCA were prepared. The same concrete mixes were prepared again but with the addition of an air entraining admixtures (AEA). All specimens were tested for compressive strength after a curing period of 7, 14, and 28 days. The compressive strength of the concrete made with different percentage of RCA decreases as the percentage of RCA increases. After 28 days of curing, samples with 0, 40, and 100% replacement of NCA with RCA were placed in the freeze-thaw chamber along with 0, 20, 40, 60, 80, and 100% NCA replacement containing AEA. After several cycles of freezing and thawing; the RDM, change in weight and change in length were measured. In this study loss of RDM and weight loss were noticed, as the cyclic freeze-thaw increases. It has also been observed that concrete mixes containing AEA were still durable after 300 cycles of freezing and thawing; however, the specimens without AEA failed before 150 cycles.
机译:冻融循环是影响混凝土耐久性的最大破坏因素之一。循环冻融作用造成的破坏可分为两个因素。第一个因素是内部裂缝的增加,这会导致混凝土的相对动态模量(RDM)损失,第二个因素是表面结垢,这会导致混凝土的重量损失。在这项研究中,通过用各种百分比的再生混凝土骨料(RCA)代替天然粗骨料(NCA)制成的混凝土的耐久性。另外还进行了一些测试,添加了引气剂(AEA)。在搅拌混凝土之前,先对NCA和RCA进行表征,以确定它们是否适合用作建筑材料。制备了由RCA替代0、20、40、60、80和100%(按重量计)NCA的混凝土混合物。再次制备相同的混凝土混合物,但是添加引气剂(AEA)。在固化7天,14天和28天后测试所有样品的抗压强度。随着RCA百分比的增加,使用不同RCA百分比制成的混凝土的抗压强度会降低。固化28天后,将用RCA替代0、40和100%的NCA的样品与包含AEA的0、20、40、60、80和100%替代NCA的样品一起放入冻融室。经过几次冷冻和解冻;测量RDM,重量变化和长度变化。在该研究中,随着循环冻融的增加,注意到RDM的损失和体重减轻。还已经观察到,含有AEA的混凝土混合物经过300次冷冻和融化后仍然耐久。但是,没有AEA的标本在150次循环之前就失效了。

著录项

  • 作者

    Sulaiman, Salman.;

  • 作者单位

    Southern Illinois University at Carbondale.;

  • 授予单位 Southern Illinois University at Carbondale.;
  • 学科 Civil engineering.;Environmental engineering.
  • 学位 M.S.
  • 年度 2016
  • 页码 94 p.
  • 总页数 94
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:41:01
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号