首页> 外文学位 >On the Binding Stress-Enhanced Sensitivity of (Pb(Mg1/3Nb2/3)O3)0.65-(PbTiO3) 0.35 (PMN-PT) Piezoelectric Plate Sensor (PEPS).
【24h】

On the Binding Stress-Enhanced Sensitivity of (Pb(Mg1/3Nb2/3)O3)0.65-(PbTiO3) 0.35 (PMN-PT) Piezoelectric Plate Sensor (PEPS).

机译:关于(Pb(Mg1 / 3Nb2 / 3)O3)0.65-(PbTiO3)0.35(PMN-PT)压电板传感器(PEPS)的结合应力增强的灵敏度。

获取原文
获取原文并翻译 | 示例

摘要

(Pb(Mg1/3Nb2/3)O3)0.65-(PbTiO 3)0.35 (PMN-PT) piezoelectric plate sensor (PEPS) showed enhanced sensitivity in chemical and biological sensing applications which has been attributed to binding-induced crystalline orientation switching in the PMN-PT layer. However, so far there has been no direct demonstration of PEPS crystalline orientation switching upon target-analyte binding. Using biotin and streptavidin binding as a model detection system and by direct X-Ray diffraction observations after analyte binding we have unambiguously demonstrated that switching of the crystalline orientations of the PMN-PT layer indeed occurred. In addition, we have shown that PEPS sensitivity enhancement increased with an increasing transverse electromechanical coupling constant, -k31, of the PMN-PT layer--which is known to correlate with the crystalline orientation switching capability--by increasing the grain size of the PMN-PT layer or by applying a DC bias electric field. Finally, unprecedented high sensitivity of PEPS with high -k31, (i.e., -k31 > 0.3) were illustrated by the aM (10-18 M) sensitivity of in situ DNA hybridization detection without amplification and by the 100 fg/ml (10-13 g/ml) sensitivity of rapid, in situ protein detection in biological fluids such as troponin I detection in serum for early sign of myocardial infarction (heart attack), Her2 detection in serum for cancer treatment and monitoring, Tn antigen and anti-Tn antibody detection in serum for early cancer detection, and Toxins detection in stool for Clostridium difficile infection detection.
机译:(Pb(Mg1 / 3Nb2 / 3)O3)0.65-(PbTiO 3)0.35(PMN-PT)压电板传感器(PEPS)在化学和生物传感应用中显示出增强的灵敏度,这归因于结合诱导的晶体取向转换PMN-PT层。然而,到目前为止,还没有直接证明在靶标-被分析物结合后PEPS结晶取向转换。使用生物素和链霉亲和素结合作为模型检测系统,并通过分析物结合后的直接X射线衍射观察,我们明确地证明了确实发生了PMN-PT层晶体取向的转换。此外,我们已经表明,通过增加PMN-PT层的晶粒尺寸,PMN-PT层的横向机电耦合常数-k31会增加PEPS灵敏度,而后者又与晶体取向转换能力相关。 PMN-PT层或通过施加直流偏置电场。最后,通过无扩增的原位DNA杂交检测的aM(10-18 M)灵敏度和100 fg / ml(10-g),说明了具有高-k31(即-k31> 0.3)的PEPS前所未有的高灵敏度。 13 g / ml)在生物液体中快速进行原位蛋白检测的敏感性,例如血清中的肌钙蛋白I检测对心肌梗死(心脏病)的早期征兆,血清中的Her2检测(用于癌症治疗和监测),Tn抗原和抗Tn血清中的抗体检测可用于早期癌症检测,粪便中的毒素检测可用于艰难梭菌感染检测。

著录项

  • 作者

    Wu, Wei.;

  • 作者单位

    Drexel University.;

  • 授予单位 Drexel University.;
  • 学科 Materials science.
  • 学位 Ph.D.
  • 年度 2016
  • 页码 188 p.
  • 总页数 188
  • 原文格式 PDF
  • 正文语种 eng