首页> 外文学位 >Development of an instrument to measure usability of assistive technology devices.
【24h】

Development of an instrument to measure usability of assistive technology devices.

机译:开发一种用于测量辅助技术设备可用性的工具。

获取原文
获取原文并翻译 | 示例

摘要

Usability of assistive technology (AT) devices determines how effectively and efficiently AT users with disabilities can participate in various activities. This research program (dissertation) involved the conceptualization of the Usability Scale for Assistive Technology (USAT), and the development of the Wheeled Mobility module of the USAT, USAT-WM, as a tool to capture user-centered usability of wheeled-mobility devices.;In human factors science, usability is considered to be an outcome of the interaction of the user with the product (AT ) to accomplish a task (or activity) under the influence of an environment. On this theme, a qualitative inquiry was conducted with users of AT devices focusing on their experiences with use of AT. The interview content was coded and nearly 400 indicators pertaining to wheeled-mobility AT devices were assimilated to construct a preliminary version of the USAT-WM. The content validity of the USAT-WM was evaluated by a panel of clinicians in the field of wheeled-mobility. The findings from the content validation process were utilized to revise the USAT-WM.;A field-test of the USAT-WM was conducted by administering it to 70 individuals who used power wheelchairs (PWCs) for mobility. A preliminary principal component analysis of the instrument sections was performed, and based on the item loading a subsequent factor analysis was conducted to establish a 50-item version of the USAT-WM with seven subscales: home usability; workplace/school usability; community usability; outdoor usability; ease of use; seating; and safety. Internal consistency Cronbach's alpha values for the seven subscales ranged from 0.77 to 0.91 and 0.90 for the total score of the USAT-WM. The test-retest and alternate-form reliability of the USAT-WM scores correlated at 0.85 (p0.01). The convergent validity correlations of the USAT-WM with the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST2.0) and the Psychosocial Impact of Assistive Devices Scale (PIADS) were found to be 0.55 (p0.01) and 0.30 (p0.01) respectively. In order to promote the applicability of the USAT-WM, an intervention framework has been proposed. A descriptive analysis of the field-test data was conducted to identify and map usability issues associated with PWCs to this framework.
机译:辅助技术(AT)设备的可用性决定了残疾用户AT如何有效地参与各种活动。该研究计划(论文)涉及辅助技术可用性量表(USAT)的概念化,以及USAT-WM的USAT轮式移动模块的开发,该工具可捕获以用户为中心的轮式移动设备的可用性在人为因素科学中,可用性被认为是用户与产品(AT)交互以在环境的影响下完成一项任务(或活动)的结果。关于这个主题,对AT设备的用户进行了定性询问,重点是他们使用AT的经验。对采访内容进行了编码,并吸收了与轮式AT设备有关的近400个指标,以构建USAT-WM的初步版本。 USAT-WM的内容效度由轮式机动领域的一组临床医生评估。内容验证过程中的发现被用于修订USAT-WM。通过对70名使用电动轮椅(PWC)进行机动性的个人进行USAT-WM的现场测试。对仪器部分进行了初步的主成分分析,然后根据装载的物料进行了后续的因素分析,以建立具有70个子量表的USAT-WM的50个项目版本:居家可用性;工作场所/学校的可用性;社区可用性;户外可用性使用方便;座位和安全。内部一致性七个子量表的Cronbachα值在USAT-WM总分中介于0.77至0.91和0.90之间。 USAT-WM分数的重新测试信度和替代形式信度为0.85(p <0.01)。发现USAT-WM与魁北克用户对辅助技术满意度(QUEST2.0)和辅助设备的心理社会影响量表(PIADS)的收敛效度相关性分别为0.55(p <0.01)和0.30(p < 0.01)。为了促进USAT-WM的适用性,提出了一种干预框架。对现场测试数据进行了描述性分析,以识别与PWC相关的可用性问题并将其映射到此框架。

著录项

  • 作者

    Arthanat, Sajay.;

  • 作者单位

    State University of New York at Buffalo.;

  • 授予单位 State University of New York at Buffalo.;
  • 学科 Health Sciences Rehabilitation and Therapy.;Engineering Biomedical.
  • 学位 Ph.D.
  • 年度 2007
  • 页码 156 p.
  • 总页数 156
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 11:39:19

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号