The Americans with Disabilities Act (ADA) of 1990 and the aging of the U.S. population has increased the attention given to the accessibility of public buildings to disabled individuals. Automated doors are a common method for providing access for the disabled, and their low energy operated counterparts offer a cost and possible energy savings over full automation. These doors, activated by the press of a button, are regulated by ADA code through an ANSI/BHMA standard.;The purpose of this study was to measure the compliance of the doors as used in public, and to evaluate the standards that apply to these entryways. Doors were selected from different neighborhoods around the city of Cincinnati, Ohio from different categories of buildings (medical, education, government, recreation/arts, commercial/office, and retail/banking). Door opening times, location of the actuator, closing forces, and other physical attributes were recorded for each of 55 doors at 31 unique locations. Disabled door users experienced with one or more assistive devices were consulted to attempt to establish a link between door opening times and perceived difficulty of negotiating the doorway.;39% of the doors measured by the author were found to be noncompliant with ADA code in some way. The analysis suggests that there is no significant relationship between the perceived difficulty of the doorway and the time allowed for entry. The study recommends several simple and easy to implement changes to the ANSI/BHMA standard that can increase the safety and accessibility of many of these low energy power operated doors.
机译:1990年的《美国残疾人法案》(ADA)和美国人口的老龄化,使人们更加关注公共建筑对残疾人的可及性。自动门是为残障人士提供通行的一种常用方法,而其低能耗操作的门则比全自动化更节省成本并节省能源。这些按一下按钮即可激活的门由ADA代码通过ANSI / BHMA标准进行调节。这项研究的目的是测量公共使用的门的合规性,并评估适用于公共场所的标准。这些入口。大门是从俄亥俄州辛辛那提市周围的不同社区中从不同类别的建筑物(医疗,教育,政府,娱乐/艺术,商业/办公以及零售/银行)中选择的。记录了55个门在31个唯一位置上的每个门的打开时间,执行器位置,关闭力以及其他物理属性。咨询了使用过一个或多个辅助装置的残疾门使用者,以试图在开门时间和感觉到的协商门道困难之间建立联系。;作者发现39%的门在某些情况下不符合ADA规范道路。分析表明,在所感觉到的门口困难与进入时间之间没有显着关系。研究建议对ANSI / BHMA标准进行几项简单易行的更改,这些更改可以提高许多这些低能耗电动门的安全性和可及性。

著录项

  • 作者

    Wiggermann, Neal.;

  • 作者单位

    University of Cincinnati.;

  • 授予单位 University of Cincinnati.;
  • 学科 Engineering Industrial.
  • 学位 M.S.
  • 年度 2007
  • 页码 109 p.
  • 总页数 109
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 一般工业技术;
  • 关键词

  • 入库时间 2022-08-17 11:39:21

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号