首页> 外文学位 >Investigation of information processing and cognitive performance capacities with different instrumentation configurations.
【24h】

Investigation of information processing and cognitive performance capacities with different instrumentation configurations.

机译:调查不同仪器配置的信息处理能力和认知能力。

获取原文
获取原文并翻译 | 示例

摘要

The focus of this thesis is the investigation of two new performance capacity tests related to a concept known as "situational awareness": (1) Visual Motor Multitask Performance Capacity (VMMPC) and (2) Visual Auditory Information Processing Dexterity (VAIPD). These represent major components of human information processing and are therefore important in situations ranging from driving and other activities of daily living to occupational and sport tasks. These tests have been recently designed and implemented on a laboratory-based instrument called the BEP I. In the present project, they are implemented on a different, more portable platform that is under development and known as the Human Performance Multimeter (HPMM). Both lab-based and HPMM implementations of the tests were evaluated for reliability and evidence of validity in an experiment involving twenty healthy adult volunteers (10 males, 21 to 60 years, mean---28.6 years; 10 females, 22 to 27 years, mean---23.9 years). A test-retest paradigm was used. Good test-retest reliability (repeatability) was obtained for both implementations (r > 0.70) for most measures and VAIPD reliability generally better than VMMPC reliability. Performance capacity values obtained from the HPMM were found to be comparable to those obtained with the BEP I. VAIPD measures did not correlate with VMMPC results, suggesting that each test measures a different capacity. It is concluded that the current test designs are fundamentally sound and that these tests hold promise for efficient characterization of important performance capacities that may eventually impact neurology, physical therapy, rehabilitation, vocational, and other domains where human information processing is of interest.
机译:本文的重点是对与称为“情境意识”的概念相关的两个新的性能能力测试的研究:(1)视觉运动多任务性能能力(VMMPC)和(2)视觉听觉信息处理敏捷性(VAIPD)。这些代表了人类信息处理的主要组成部分,因此在从驾驶和其他日常活动到职业和运动任务等各种情况下都非常重要。这些测试最近已经在称为BEP I的基于实验室的仪器上进行了设计和实施。在本项目中,它们在不同的,更便携的平台上实施,该平台正在开发中,被称为“人类性能万用表”(HPMM)。在涉及20名健康成人志愿者的实验中评估了基于实验室的测试和HPMM实施的可靠性和有效性证据(10名男性,年龄21至60岁,平均--28.6岁; 10名女性,年龄22至27岁,平均--23.9年)。使用了测试-再测试范例。对于大多数措施,两种实现方式都具有良好的重测可靠性(可重复性)(r> 0.70),并且VAIPD可靠性通常优于VMMPC可靠性。发现从HPMM获得的性能能力值与通过BEP I获得的性能能力值相当。VAIPD量度与VMMPC结果不相关,表明每种测试所测量的能力不同。结论是,当前的测试设计在根本上是合理的,并且这些测试有望有效表征重要的性能,这些性能最终可能会影响神经学,物理疗法,康复,职业以及其他涉及人类信息处理的领域。

著录项

  • 作者

    Mathew, Saju John.;

  • 作者单位

    The University of Texas at Arlington.;

  • 授予单位 The University of Texas at Arlington.;
  • 学科 Biomedical engineering.
  • 学位 M.S.
  • 年度 2007
  • 页码 146 p.
  • 总页数 146
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号