This study characterizes the response of the human cadaver abdomen to high-speed seatbelt pretensioner loading. A test apparatus was developed to deliver symmetric loading to the abdomen using a seatbelt equipped with two low mass load cells. Eight human cadaveric subjects were tested, as well as 5 Hybrid III 50th tests, and 7 tests with the Thor Alpha ATD. The tests were configured in a worst-case, out-of-position (OOP) scenario. A seatbelt was placed at the level of mid-umbillicus, and drawn back along the sides of the test subjects, which were seated in an upright fixed-back configuration. Penetration of the seatbelt was measured by a laser, which tracked the anterior aspect of the abdomen, and by high-speed video. Additionally, aortic pressure was monitored in the cadaveric subjects. Four different pretensioner system designs were used, referred to as system A, system B, system C, and system D. The B, C, and D systems employed single pretensioners. The A system consisted of two B system pretensioners. The vascular system of the cadaver subjects were perfused. For the cadaveric subjects: Peak anterior abdominal loads ranged from 2.8 kN to 10.1 kN. Peak abdominal penetration ranged from 49 mm to 138 mm. Peak penetration speed ranged from 4.0 m/s to 13.3 m/s. Three cadavers sustained liver injury: one AIS 2, and two AIS 3. Cadaver abdominal response corridors for the A and B system pretensioners are proposed. The results are compared to the data reported by Hardy (2001) and Trosseille (2002). The response of the Hybrid III 50th ATD that was fitted with a silicone abdominal insert, and the Thor Alpha ATD are compared to the B-system corridors. Additionally a Madymo model utilizing the Thor Alpha was developed to simulate the response of the cadavers and the Thor Alpha.
机译:这项研究的特点是人体尸体腹部对高速安全带预紧器负荷的反应。开发了一种测试设备,可使用配备有两个低质量测力传感器的安全带将对称负载传递至腹部。测试了八名人类尸体受试者,以及五项Hybrid III 50th测试和七项使用Thor Alpha ATD进行的测试。这些测试是在最坏的情况下(OOP)情况下配置的。将安全带放置在脐带中部,并沿着被测者的侧面向后拉,被测者以直立的固定式靠背姿势就座。激光跟踪腹部的前侧情况,并通过高速视频测量安全带的穿透程度。另外,在尸体受试者中监测主动脉压。使用了四种不同的预张紧器系统设计,分别称为系统A,系统B,系统C和系统D。B,C和D系统采用单个预张紧器。 A系统由两个B系统预张紧器组成。尸体受试者的血管系统被灌注。对于尸体受试者:前腹峰值负荷范围从2.8 kN到10.1 kN。腹部最大穿刺深度为49毫米至138毫米。峰值穿透速度为4.0 m / s至13.3 m / s。建议三名尸体遭受肝损伤:一个为AIS 2,两个为AIS3。建议使用A和B系统预张紧器的尸体腹部响应通道。将结果与Hardy(2001)和Trosseille(2002)报告的数据进行比较。将装有有机硅腹部插入物的Hybrid III 50th ATD和Thor Alpha ATD的响应与B系统走廊进行比较。此外,还开发了利用Thor Alpha的Madymo模型来模拟尸体和Thor Alpha的响应。

著录项

  • 作者

    Foster, Craig D.;

  • 作者单位

    Wayne State University.;

  • 授予单位 Wayne State University.;
  • 学科 Engineering Automotive.;Engineering Biomedical.
  • 学位 M.S.
  • 年度 2007
  • 页码 136 p.
  • 总页数 136
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 自动化技术及设备;生物医学工程;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号