首页> 外文会议>The 2nd International Conference on Bioinformatics and Biomedical Engineering(iCBBE 2008)(第二届生物信息与生物医学工程国际会议)论文集 >Research of spectrophotometer for bio-chemical analyzer based on automatic adjustment of the integration time of linear CCD
【24h】

Research of spectrophotometer for bio-chemical analyzer based on automatic adjustment of the integration time of linear CCD

机译:基于线性CCD积分时间自动调节的生化分析仪分光光度计的研究

获取原文

摘要

The bio-chemical analyzer (BCA) is a kind of instrument which is used to measure some clinical or chemical targets in samples (blood). Since light source's energy is different and samples have different spectrum absorbance in different wavelength. Energy attenuation of ultraviolet (UV) wavelength is large; otherwise, The noise which exist in the electronic circuits and the astigmatism which exist in the ray-route system,both of which will reduce the luminosity nicety in the UV wave-band. In this paper, Virtual Instrument(VI) technique and the method of software optimizing algorithm are used to enhance measurement veracity of the luminosity value, and the exposure time of linear CCD is auto-adjusted to expose separately for strong light and week light. From experiment results, we can obtain that the capability and signal to noise ratio (SNR) of the system are greatly improved, the spectrum range of spectrophotometer for BCA can reach 300~800nm and the distinguish of wavelength is less than 10nm.
机译:生化分析仪(BCA)是一种用于测量样品(血液)中某些临床或化学指标的仪器。由于光源的能量不同,并且样品在不同波长下具有不同的光谱吸收率。紫外线(UV)波长的能量衰减很大;否则,电子线路中存在的噪声和射线路径系统中存在的像散,都会降低紫外线波段的发光度。本文采用虚拟仪器(VI)技术和软件优化算法的方法来提高光度值的测量准确性,并自动调整线性CCD的曝光时间,以分别对强光和周光进行曝光。从实验结果可以看出,该系统的性能和信噪比(SNR)得到了很大的提高,BCA分光光度计的光谱范围可以达到300〜800nm,波长分辨度小于10nm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号