Studies on Carbon Mediated Paste Screen Printed Sensors for Blood Glucose Sensing Application

机译:碳介导的糊状丝网印刷传感器在血糖传感中的应用研究

获取原文
获取原文并翻译 | 示例

摘要

Ready-to-use screen printed glucose sensors are fabricated using Prussian Blue (PB) and Cobalt Phthalocyanine (CoPC) mediated carbon paste as working electrodes. The reference and counter electrodes are screen printed using silver/silver chloride and graphitic carbon paste respectively. The screen printed reference electrode (internal reference electrode (IRE)) is found to be stable for more than 60 minute when examined with standard calomel electrode. Optimal operating voltage for PB and CoPC screen printed sensors as determined by hydrodynamic voltammetric technique. The sensing characteristics of the fabricated sensors towards H_2O_2 are conducted and response found to be good. Glucose oxidase is immobilized on the working electrodes by cross-linking method. PB mediated glucose sensor exhibits a sensitivity of 5.60 mAcm~(-2)/mM for the range 10 to 1000 uM. Sensitivity CoPC mediated glucose sensor are found to be 5.224 μAcm~(-2)/mM. The amperometeric response is linear for the range, 100 to 1500 μM. Interference studies on the fabricated glucose sensors are conducted with species like uric acid and ascorbic acid. PB mediated sensors showed a completely interference-free behavior; while CoPC mediated sensors are influenced by uric acid and ascorbic acid due to higher operating voltage. The sensing characteristics of PB mediated glucose sensors are also studied in diluted human serum samples and the results are compared with the values obtained by standard clinical method. The co-efficient of variation found to be less than 5 %.
机译:现成的丝网印刷葡萄糖传感器使用普鲁士蓝(PB)和酞菁钴(CoPC)介导的碳糊作为工作电极制成。参比电极和对电极分别使用银/氯化银和石墨碳浆料进行丝网印刷。使用标准甘汞电极检查时,发现丝网印刷的参比电极(内部参比电极(IRE))在60分钟以上稳定。通过流体动力学伏安法确定的PB和CoPC丝网印刷传感器的最佳工作电压。进行了所制造的传感器对H_2O_2的感测特性,发现响应良好。葡萄糖氧化酶通过交联法固定在工作电极上。 PB介导的葡萄糖传感器在10至1000 uM范围内的灵敏度为5.60 mAcm〜(-2)/ mM。 CoPC介导的葡萄糖传感器的灵敏度为5.224μAcm〜(-2)/ mM。在100至1500μM的范围内,电流响应是线性的。用诸如尿酸和抗坏血酸之类的物质对制成的葡萄糖传感器进行干扰研究。 PB介导的传感器表现出完全无干扰的行为;而CoPC介导的传感器由于较高的工作电压而受到尿酸和抗坏血酸的影响。在稀释的人血清样品中还研究了PB介导的葡萄糖传感器的传感特性,并将结果与​​标准临床方法获得的值进行了比较。发现变化系数小于5%。

著录项

  • 来源
  • 会议地点 Chicago IL(US)
  • 作者单位

    Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore - 560012, India;

    Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore - 560012, India;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-26 14:20:22

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号