首页> 外文会议>Recent Development of Modeling of Casting and Solidification Processes >COUPLED NUMERICAL SIMULATION OF FLOW FIELD AND TEMPERATURE FIELD FOR INNER-OUTER COUPLED COOLING SLAB CONTINUOUS CASTING
【24h】

COUPLED NUMERICAL SIMULATION OF FLOW FIELD AND TEMPERATURE FIELD FOR INNER-OUTER COUPLED COOLING SLAB CONTINUOUS CASTING

机译:内外耦合冷却板连铸流场与温度场的耦合数值模拟

获取原文
获取原文并翻译 | 示例

摘要

An inner-outer coupled cooling technology of molten steel for 1240x200mm slab continuous casting, that is to set an inner cooler-U shape pipes in the mold, is put forward in order to enhance the efficiency of transmitting heat and improve inner structure of billet. The solidification status of molten steel under coupling flow field and temperature field in inner-outer coupled cooling mold is simulated by using fluid dynamics software. It is found that setting inner cooler in the mold can make molten steel flow status even, which is favourable to the inclusion's floating up, quickening the solidification of steel liquid and improving the quality of billet.
机译:为了提高传热效率,改善钢坯内部结构,提出了一种用于1240x200mm板坯连铸的钢水内外耦合冷却技术,即在模具中设置内冷却器U形管。利用流体动力学软件,模拟了内外耦合冷却模具中耦合流场和温度场下钢水的凝固状态。发现在模具中设置内部冷却器可以使钢水均匀流动,有利于夹杂物的浮起,加快钢液的凝固速度,提高钢坯质量。