首页> 外文会议>The Progress of Green Oxidation/Reduction Technologies >Low Temperature Plasma Application to Treat Malodor of Sewage Plant
【24h】

Low Temperature Plasma Application to Treat Malodor of Sewage Plant

机译:低温等离子体处理污水厂恶臭

获取原文
获取原文并翻译 | 示例

摘要

According to the malodor origin and the component of some sewage treatment plant, the article uses the low temperature plasma technology to decompose the malodor. It achieves the controlling goal of malodor. It introduces the low temperature plasma technology, and explains the equipment design conditions of deodorization, the system flow, the craft parameter from the project application. The result of the project implementation has shown that the removal rates of H_2S, NH_3, CH_3-SH may achieve 81.3%, 88.1%, 84.4% respectively.
机译:根据恶臭的来源和某些污水处理厂的组成,本文采用低温等离子体技术分解恶臭。它达到了控制恶臭的目的。介绍了低温等离子体技术,并从工程应用中说明了除臭的设备设计条件,系统流量,工艺参数。项目实施结果表明,H_2S,NH_3,CH_3-SH的去除率可分别达到81.3%,88.1%,84.4%。