The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compres-sionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360° in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue contrast and reduced speckle compared to conventional US images. Although scanner performance is satisfactory, additional developments including reduced spacing transducer - scanned object spacing and corrections for sound velocity and aberrations will improve operation. Future work will continue system optimization.
机译:该项目的目的是设计,构建和表征对悬垂乳房成像的体积乳房超声(VBUS)扫描仪的性能。 VBUS扫描仪的设计包括:1)临床超声扫描仪和换能器; 2)扫描台上有一个用于吊坠乳房的孔; 3)旋转龙门架; 4)探头安装组件; 5)无压乳房稳定器; 6)采集,控制,重建和显示软件。性能评估的特征是各种参数,包括:在水平和垂直扫描模式下使用高对比度和低对比度测试对象的空间分辨率,均匀性和失真。 VBUS扫描仪模块已构建并评估了初始性能。在18秒内在360°范围内进行了大约300次扫描。每片重建需要25 ms。与传统的美国图像相比,测试对象图像描绘了高回声和低回声的肿块,并显示出良好的分辨率,软组织对比度和斑点减少。尽管扫描仪的性能令人满意,但包括减小间距的换能器-扫描的物体间距以及声速和像差校正在内的其他开发将改善操作。未来的工作将继续系统优化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号