One of the major sources of water intrusion in buildings is through openings in walls caused by windows and other fenestrations, in particular the interface between the window and wall. Numerous flashing products, including self-adhered products, have recently been developed to protect this window-wall interface from moisture intrusion. However, the proper installation of these flashing products is not well understood and installation methods are often misused. Various installation methods have been developed and tested to evaluate performance and ease of installation. While most of the flashing installation development has been focused on residential flanged-style windows, effective installation methods for wood framed "brick mold" windows as well as other "nonflanged" windows have not previously been developed and tested. A series of laboratory wall tests were used to compare the air leakage resistance (ASTM E 283), water leakage resistance (ASTM E 331), and durability (ASTM E 330) of various flashing materials and installation methods. The performance and durability of flashing as installed with round top windows, brick mold windows, and nonflanged windows were tested and evaluated.
机译:建筑物中水侵入的主要来源之一是通过窗户和其他窗孔(尤其是窗户和墙壁之间的界面)造成的墙壁开口。最近已经开发出许多防水产品,包括自粘产品,以保护该窗-墙界面免受湿气侵入。但是,对于这些防水产品的正确安装尚不甚了解,因此经常会滥用安装方法。已经开发和测试了各种安装方法,以评估性能和安装简易性。尽管大多数防水安装开发都集中在住宅的法兰式窗户上,但是木框“砖模”窗户以及其他“非法兰”窗户的有效安装方法尚未得到开发和测试。一系列的实验室墙壁测试用于比较各种防水材料和安装方法的耐漏气性(ASTM E 283),耐漏水性(ASTM E 331)和耐久性(ASTM E 330)。测试并评估了安装在圆顶窗户,砖模窗户和无凸缘窗户上的防水板的性能和耐用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号