THE METHOD OF PRESTRESS LEVEL EVALUATING FOR CABLE DOME

机译:索穹顶预应力水平评估方法

获取原文
获取原文并翻译 | 示例

摘要

The construction of cables is the key technique of the cable dome. During the actual construction process,rnhowever, it difficult to ensure that there is no difference between the real prestressed force and the design value,rnthat is, the prestress level of cables is not uniform. Thus it is necessary for construction team to regulate the realrnprestress of cables repeatedly, but the result is not satisfactory. For construction team, so it is necessary to checkrnand test whether the actual prestress level satisfy the design requirements or not, and a clear judgment is need tornmade. To solve the problem, in the present work, a mathematical statistic method is adopted to evaluate the levelrnof prestress distributed non-uniformly for cable dome and the evaluation criterion is presented. The numericalrnresults show that the evaluating method is correct and feasible and it is therefore helpful to guide thernconstruction of cable dome.
机译:电缆的构造是电缆穹顶的关键技术。但是,在实际施工过程中,很难保证实际的预应力与设计值之间没有差异,即电缆的预应力水平不均匀。因此施工队有必要反复调节电缆的实际预应力,但效果并不理想。对于施工队来说,有必要检查和测试实际的预应力水平是否满足设计要求,需要做出明确的判断。为了解决该问题,在本文中,采用一种数学统计方法来评估缆索穹顶的水平预应力分布不均匀,并提出了评估标准。数值结果表明,该评价方法是正确可行的,对指导电缆穹顶的施工具有指导意义。

著录项

  • 来源
  • 会议地点 Beijing(CN)
  • 作者单位

    Professor, Spatial Structures Research Center, Beijing University of Technology, Beijing 100022, China;

    PH.D. Candidate, Spatial Structures Research Center, Beijing University of Technology, Beijing 100022, China;

    Professor, School of Civil Engineering, Inner Mongolia Polytechnic University, Hohhot 010062, China;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 TU984.113;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号