Instantaneous temperature field measurement on a hot surface cooled by impinging jet using thermographic phosphor technique

机译:通过使用热选磷技术冲击喷射器冷却热表面上的瞬时温度场测量

获取原文

摘要

Thermographic phosphor thermometry was used to measure the instantaneous temperature field of a hot plate cooled by an oblique impinging air jet. For phosphor thermometry, the manganese-activated magnesium fluorogermanate (Mg_4FGeO_6:Mn) was used as a thermographic phosphor, and a pulsed UV-LED with a 385 nm wavelength was used for the light source. A CMOS high speed camera acquired the phosphorescence images with a 655 nm band-pass filter. A simple and fast calibration method for phosphor thermometry using decay constant was suggested and the results were compared to the conventional lifetime based method. In-situ pixel by pixel calibration procedure was adopted to avoid non-uniform illumination problem. The instantaneous two-dimensional imaging of temperature field on the hot plate was visualized in the transient process after starting the impinging air jet cooling.
机译:热成像热体用于测量通过倾斜撞击空气射流冷却的热板的瞬时温度场。对于磷光体温度,使用锰活化的氟代镁(Mg_4FGeO_6:Mn)作为热成像磷光体,并且使用具有385nm波长的脉冲UV-LED用于光源。 CMOS高速摄像机获取具有655nm带通滤波器的磷光图像。建议使用衰减恒定的磷光体温度的简单且快速校准方法,并将结果与​​常规寿命的方法进行了比较。采用像素校准过程的原位像素避免了不均匀的照明问题。在启动冲击空气喷射冷却之后,在瞬态过程中可视化热板上温度场的瞬时二维成像。