Objective Measurement of Dynamic Balance Function by the Simultaneous Measurement of the Center of Gravity (COG) and Center of Pressure (COP)

机译:通过同时测量重心(COG)和压力中心(COP)的同时测量动态余量功能的客观测量

获取原文

摘要

Although a posturography is commonly used for objective evaluation of static balance function, dynamic balance function is usually evaluated only with clinical scales. Simplified objective measurement systems for the evaluation of dynamic balance function need to be developed. In this preliminary study, we attempted to develop an index for the objective measurement of dynamic balance function from COP-COG data. The subjects comprised nine hemiparetic post-stroke patients and five healthy subjects. The simultaneous measurements of COG and COP were performed using a three-dimensional motion analysis system (Kinema-tracer, KisseiComtec, Japan) combined with force plate analysis. As indices for evaluating dynamic balance function, the latency of COP passing COG after heel contact (LCP) and the averaged |COP| - |COG| subtraction value during stance phase (ASV) were calculated. For evaluating validity of the measurement, the Berg Balance Scale, a frequently used clinical balance scale, was used. The results showed significant differences (0.13±0.02 vs. 0.29±0.23 s) between the healthy subjects and patients in LCP, and large, yet insignificant, differences (4.3 ± 0.5 vs. 2.7 ± 2.0 cm) in ASV. The ASV was strongly correlated with BBS. A strong correlation was observed between COG acceleration and ASV, except in one patient, who had a severe balance disorder. These results may encourage further investigation into the feasibility of COP-COG measurements for balance measurement.
机译:虽然姿势图是常用的静态平衡功能的客观评价,动态的平衡功能通常只与临床量表评估。待开发的动态平衡功能需要评估简化客观测量系统。在此初步研究中,我们试图发展动态的平衡功能,从COP-COG数据的客观测量的指标。研究对象包括9偏瘫在中风后的患者和五个健康受试者。使用具有测力板分析相结合的三维运动分析系统(的kinema示踪剂,KisseiComtec,日本)进行COG和COP的同时测量。作为指数评价动态平衡功能,COP通过COG脚跟触地(LCP)后的等待时间和平均| COP | - | COG |在步态站立期(ASV)减法值进行了计算。对于评估测量的有效性,Berg平衡量表,经常使用的临床天平秤,使用。结果表明:健康受试者和患者之间的差异显著(0.13±0.02对比0.29±0.23 S)在LCP,和大的,但不显着,在差ASV(4.3±0.5与2.7±2.0厘米)。该ASV是紧密联系在一起BBS相关。 COG加速和ASV之间观察到强相关性,除了在一个病人,谁得了严重的平衡障碍。这些结果可能会鼓励进一步调查COP-COG测量的平衡测量的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号