In recent years'special attention has been paid to energy conservation.The need to reduce the consumption of mineral raw materials and fossil organic fuel is primarily associated with a reduction their reserves and,consequently,a constant increase in the cost.Therefore,a very actual task is to reduce the energy costs for heating and ventilation of industrial enterprises.The use of on duty heating during the non-working period can significantly increase the energy efficiency of an industrial building.On the basis the thermal regime of an industrial building,considered in the article,is shown the need to develop an engineering method for calculating the process of non-stationary heat transfer in buildings operated with a stand-by heating mode.This article presents the method of heat engineering calculation of building enclosing structures used in buildings with variable power of the heating system,which allows to determine the minimum allowable thickness of insulation from the condition of limiting the heating time of the outer wall.An example of the design calculation of the wall sandwich panel an industrial building is considered.An assessment of the specific energy consumption for heating external walls was made.A study conducted by the authors,allows to determine the range of thickness the enclosing structures,operated in conditions of a variable thermal regime.
机译:近年来,已经支付了节约能源的特别关注。需要降低矿物原料和化石有机燃料的消耗主要与其储备减少相关,从而持续增加成本。因此,非常实际任务是降低工业企业供暖和通风的能源成本。在非工作期间使用值班加热可以显着提高工业建筑的能源效率。该工业建筑的热制度基础,示出了在本文中考虑的是需要开发一种用于计算用待机加热模式操作的建筑物中非平稳传热过程的工程方法。本文提出了用于建筑物封闭结构的热工程计算方法具有加热系统可变功率的建筑物,允许从条件下确定绝缘绝缘的最小允许厚度限制外墙的加热时间。墙壁夹层面板的设计计算的例子被认为是工业建筑的评估。制造了对加热外墙的特定能耗的评估。作者进行了研究,允许确定封闭结构的厚度范围,在可变热状态的条件下操作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号