首页> 外文会议>AMEE 2012 >Discussions on the Principle to Reduce the Sliding Fall Rock Impact Force against Protective Structure
【24h】

Discussions on the Principle to Reduce the Sliding Fall Rock Impact Force against Protective Structure

机译:关于减少防坠落岩撞击力对保护结构原则的讨论

获取原文

摘要

Passive ductile protective system is widely used because of its better performance than buttress wall. This paper intends to determine the sliding fall rock impact force against a steel column at first. Then the rigid protective structure and ductile protective structure were compared. At last the hidden principle that passive ductile protective system can reduce the impact force was revealed. Results indicate that rings for energy dissipation in passive ductile protective system can significantly decrease the bending stiffness EI and decrease the impact force. Buttress wall encounters a lot more impact force than passive ductile protective system because of its bulkiness. Thus to ensure the buttress wall non-destructive, the thickness of buttress wall increases and it is not economic.
机译:被动韧性保护系统被广泛使用,因为它的性能比支撑墙更好。本文旨在首先确定对钢柱的滑动岩石冲击力。然后比较刚性保护结构和延性保护结构。最后,隐藏原则揭示了被动韧性保护系统可以减少冲击力。结果表明,被动延性保护系统中的能量耗散环可以显着降低弯曲刚度EI并降低冲击力。 Buttress Wall因被动延性保护系统而遇到了更多的冲击力,因为其膨胀性。因此,为了确保支撑壁无损,支撑壁的厚度增加,而且不经济。