For ground source heat pump (GSHP) system, the dynamic heat rejected to or extracted from the ground is an important parameter to analyze the heat transfer performance of ground heat exchanger (GHE). Coupled with dynamic indoor load and actual operation characteristics of heat pump unit, a method to calculate actual dynamic heat load input of GHEs was introduced and a calculation program was developed. In an actual GSHP system project, the dynamic heat load input of GHEs was calculated and used as a boundary condition, a three-dimensional heat transfer model of this GHE field was established, and then the water temperature variation of GHEs was obtained. The actual water temperature variation of GHEs was tested and it was similar to the theoretical calculation results, thus the method was validated and could be applied in the actual engineering projects.
机译:对于地源热泵(GSHP)系统,从地面被拒绝或提取的动态热是分析地热交换器(GHE)的传热性能的重要参数。加上动态室内负荷和热泵单元的实际操作特性,引入了一种计算泡沫实际动态热负荷输入的方法,并开发了计算程序。在实际的GSHP系统项目中,计算嘴的动态热负荷输入并用作边界条件,建立了该GHE场的三维传热模型,然后获得了嘴的水温变化。测试嘴的实际水温变化,类似于理论计算结果,因此该方法经过验证,可应用于实际工程项目。