首页> 外文会议>International Conference on Concentrating Solar Power and Chemical Energy Systems >Validation of Thermocline Storage Model with Experimental Data of a Laboratory-Scale Molten Salt Test Facility
【24h】

Validation of Thermocline Storage Model with Experimental Data of a Laboratory-Scale Molten Salt Test Facility

机译:具有实验室规模熔盐测试设施的实验数据的热液存储模型的验证

获取原文

摘要

The Fraunhofer ISE single-tank simulation model was parameterized and inputs were set according to the Fraunhofer ISE lab-scale storage tank in order to validate the model. The measured stratification during the charging cycle was compared to the temperature distribution of the simulated storage tank. If the effective diffusivity factor was calculated according to literature correlations, it corresponded very well with the measurement data with a mean standard deviation of 1.21%. A parameter identification for the effective diffusivity factor of the storage was performed to reduce these deviations even further. It showed that the ideal effective diffusivity factor is 150. The mean standard deviation was further reduced to 1.14 %.
机译:Fraunhofer ISE单罐仿真模型是参数化的,并根据Fraunhofer ISE实验室秤存储池设置输入,以验证模型。将计数循环期间的测量分层与模拟储罐的温度分布进行了比较。如果根据文献相关性计算有效扩散因子,则与测量数据相对应得非常良好,平均标准偏差为1.21%。执行用于存储的有效扩散系数的参数识别,以进一步降低这些偏差。结果表明,理想的有效扩散系数为150.平均标准偏差进一步降至1.14%。