首页> 外文会议>International Conference on Advances in Mechanical Engineering >An experimental study and comparitive validation of macrolayer thickness in nucleate pool boiling for horizontal copper tube heater
【24h】

An experimental study and comparitive validation of macrolayer thickness in nucleate pool boiling for horizontal copper tube heater

机译:卧式铜管加热器核心池中大叠层厚度的实验研究与比较验证

获取原文

摘要

Nucleate Pool boiling is characterised by the progression of several nucleation sites (bubble formation), which surge from distinct points on a surface, whose temperature is slightly above the liquids. To investigate and evaluate this, a pool boiling setup was fabricated with a horizontal copper tube heater of 28mm diameter by imposing cartridge heater. An analytical expression, suggested by literature helps to determine the thickness of macrolayer based on bubble diameter was used. The macrolayer thickness for water was found by measuring the bubble diameter by using Photographic and CAD method. Experiment was carried out in a stainless steel container insulated with Teflon cover to observe the bubble growth and bubble departure characteristics for the heat flux range of 1000-42,000 W/m~2. The bubble diameter were measured and the measured parameters were been used to determine the initial layer thickness, macro layer thickness and critical heat flux and validated through various models. The observed and calculated values are in good agreement as reported in various literature.
机译:核心池沸腾的特征在于几种成核位点(气泡形成)的进展,其从表面上的不同点浪涌,其温度略高于液体。为了调查和评估这一点,通过施加筒式加热器,用28mm直径的水平铜管加热器制造池沸腾设置。由文献建议的分析表达有助于确定基于气泡直径的大罗基罗层的厚度。通过使用摄影和CAD方法测量气泡直径来发现水的宏观层厚度。实验在与Teflon盖绝缘的不锈钢容器中进行,观察气泡生长和气泡脱离特性,用于热通量范围为1000-42,000W / m〜2。测量气泡直径并使用测量的参数来确定初始层厚度,宏观层厚度和临界热通量并通过各种型号验证。观察和计算的值与各种文献报告的吻合良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号