首页> 外文会议>International Conference on Manufacturing Engineering and Process >Effect of tensile load for detecting broken wires of parallel wire cable based on guided waves
【24h】

Effect of tensile load for detecting broken wires of parallel wire cable based on guided waves

机译:拉伸荷载基于引导波检测平行线缆断裂钢丝的影响

获取原文

摘要

Condition assessment of cables has gained more attention for the bridge safety. The cable is under tensile load in service. The effect of tensile load for detecting broken wires on parallel wire cable based on guided waves is investigated. The sample cable with broken wires under several levels of tensile load is detected using guided waves based on the magnetostrictive effect. The amplitude of flaw echo increases monotonically with the increasing of tension. The results indicate that the tensile load brings benefit for detecting broken wires in the parallel wire cable.
机译:电缆的条件评估已经更加关注桥接安全。电缆处于使用的拉伸载荷。研究了拉伸负荷检测基于引导波的平行线缆上的断路的效果。使用基于磁致伸缩效应的引导波检测具有碎导线的样品电缆。随着张力的增加,缺陷回声的幅度单调增加。结果表明,拉伸载荷为检测平行线缆中的断线而带来了益处。