Based on the finite element analysis, the general mechanical property tests and the CTOD (crack tip opening displacement) test of the penstock in the third deviated hole, the GB/T19624-2004, that is the criterion of safety assessment for in-service pressure vessels containing defects suggested by China, is applied to assess the five weld defects in the penstock, which experienced the failure of the pressure test. The assessment results indicate that 1# defect and 5# defect could be accepted, while the other defects should be repaired. According to the assessment results, the defects over criterion in the penstock must be repaired. After the penstock was repaired, it was checked by the ultrasonic flaw detection again. And the results indicate that all weld joints including circumferential and longitudinal weld joints in the penstock around the pipe close in the third deviated hole are acceptable, what provides a scientific basis for the second pressure test and the safe operation of the High head hydropower station.
机译:基于有限元分析,一般机械性测试,并在第三偏离孔,所述GB / T19624-2004,即安全性评估的标准为服务中压力的压力管道的CTOD(龟裂顶端张开位移)测试含有由中国建议缺陷容器,被施加到评估在压力管道,其经历的压力测试的失败的五个焊接缺陷。评估结果表明,1个#缺陷和5#缺陷是可以接受的,而其他缺陷应被修复。根据评估结果,压力钢管缺陷超过标准,必须进行修理。引水管道被修复后,它是由超声波探伤检查一遍。其结果表明,所有的焊接接头包括围绕在第三偏离孔的管道关闭压力钢管圆周和纵向焊接接头是可以接受的,什么提供第二压力试验和高水头水电站的安全运行科学依据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号