摘要

In general, vertical pumps are weak due to vibration. Components of the pump are occasionally damaged by vibration induced from a defect in bed leveling, resonance and vortex flow. It is difficult to find the root cause of vibration and figure out the factors causing it. This paper will examine how to diagnose the root cause of vibration and mechanical damage problems. A method of vibration reduction of Sea Water Make-up Pump (SWMP) in thermal power plant is represented. The causes of vibration and system stability are investigated in two different ways. The causes of vibration are investigated using eigenvalues which are numerically computed by modal analysis and rotor dynamics. The stability of the rotor bearing system is checked using eigenvalues of SWMP by rotor dynamics. The results of modal analyse are compared with those of modal testing. It is a cause of critical vibration that natural frequency of SWMP coincides with the excitation frequency of unbalanced force at operating speed. A high-amplitude vibration problem happens at such resonance and thus SWMP may be damaged. This investigation shows an approach which is able to resolve the vibration problem induced in SWMP.
机译:通常,由于振动,垂直泵弱。泵的部件偶尔被床升级,共振和涡流流动的缺陷引起的振动损坏。很难找到振动的根本原因并弄清楚导致它的因素。本文将研究如何诊断振动的根本原因和机械损伤问题。表示热电厂中海水化泵(SWMP)的振动减少方法。以两种不同的方式研究振动和系统稳定性的原因。使用模态分析和转子动力学进行数值计算的特征值来研究振动的原因。通过转子动力学使用SWMP的特征值检查转子轴承系统的稳定性。将模态分析结果与模态测试进行比较。这是临界振动的原因,即SWMP的自然频率与操作速度不平衡力的激发频率一致。在这种共振发生高幅度振动问题,因此SWMP可能被损坏。本研究表明了一种能够解决SWMP中诱导的振动问题的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号